Een ionchromatografische methode voor de bepaling van chroom(III) en chroom(IV) in drink-, grond-, regen-, en oppervlaktewater in het lage picomolbereik

2.50
Hdl Handle:
http://hdl.handle.net/10029/10286
Title:
Een ionchromatografische methode voor de bepaling van chroom(III) en chroom(IV) in drink-, grond-, regen-, en oppervlaktewater in het lage picomolbereik
Authors:
Neele J; Cleven RFMJ
Other Titles:
An ion chromatographic method for the determination of chromium(III) and chromium (IV)in drinking water, rainwater ground and surfacewater in the low picomol range
Abstract:
An automated ionchromatographic method for the simultaneous determination of low contents of trivalent and hexavalent chromium in water was developed and optimised for the valence-specific analysis of chromium in different types of water. The speciation was carried out on a mixed anion and cation exchange column of Dionex type XS5A. High sensitivity was achieved using a preconcentration of a 6 ml sample with two CG5A guard columns and a post-column reaction based on the catalytic oxidation of luminol and chemiluminescence detection. The detection limit of chromium(VI) described with the ionchromatographic system in Milli Q water is 20 ng/l (100 pmol/l). For chromium(III) the detection limit was 6 and 90 ng/l (200 and 600 pmol/l), respectively. The resolution between chromium(III) and chromium(VI) is excellent with R>10. Application of the method was tested for drinking water, rain water, groundwater and surface water. The analysis time of the chromium components is less than 30 min. The operational parameters for the method are described in an useful format.; De prestaties en de uitvoering van de valentie specifieke analyse van chroom in watermonsters wordt in dit rapport beschreven. Een geautomatiseerde ionchromatografische methode voor de gelijktijdige bepaling van lage gehalten chroom(III) en chroom(IV) in diverse typen water is ontwikkeld en geoptimaliseerd. De scheiding werd verricht met een gemengde anion- en kationwisselaarskolom van Dionex, type CS5A. Hoge gevoeligheid werd bereikt met een voorconcentrering van 6 ml monster via twee CG5A guardkolommen en met een na-kolom reactie, gebaseerd op de katalystische oxidatie van luminol, met chemilumenescentie als detectie. De aantoonbaarheidsgrenzen voor chroom(VI) in Milli-Q water werd vastgesteld en bedraagt 20 ng/l. Voor chroom(III) is dit 90 ng/l. De resolutie tussen chroom(III) en chroom(VI) is uitstekend en bedraagt 10. De methode is getest voor de toepassing van drink-, regen-, grond- en oppervlakte water. De totale duur van de analyse van de beide componenten bedraagt minder dan 30 minuten. De operationele parameters van de methode zijn in een direct bruikbaar formaat in dit rapport opgenomen.
Affiliation:
LAC
Publisher:
Rijksinstituut voor Volksgezondheid en Milieu RIVM
Issue Date:
30-Oct-1999
URI:
http://hdl.handle.net/10029/10286
Additional Links:
http://www.rivm.nl/bibliotheek/rapporten/703713006.html
Language:
nl
Series/Report no.:
RIVM Rapport 703713006
Appears in Collections:
RIVM reports - old archive

Full metadata record

DC FieldValue Language
dc.contributor.authorNeele Jen_US
dc.contributor.authorCleven RFMJen_US
dc.date.accessioned2007-03-09T17:00:11Z-
dc.date.available2007-03-09T17:00:11Z-
dc.date.issued1999-10-30en_US
dc.identifier703713006en_US
dc.identifier.urihttp://hdl.handle.net/10029/10286-
dc.description.abstractAn automated ionchromatographic method for the simultaneous determination of low contents of trivalent and hexavalent chromium in water was developed and optimised for the valence-specific analysis of chromium in different types of water. The speciation was carried out on a mixed anion and cation exchange column of Dionex type XS5A. High sensitivity was achieved using a preconcentration of a 6 ml sample with two CG5A guard columns and a post-column reaction based on the catalytic oxidation of luminol and chemiluminescence detection. The detection limit of chromium(VI) described with the ionchromatographic system in Milli Q water is 20 ng/l (100 pmol/l). For chromium(III) the detection limit was 6 and 90 ng/l (200 and 600 pmol/l), respectively. The resolution between chromium(III) and chromium(VI) is excellent with R>10. Application of the method was tested for drinking water, rain water, groundwater and surface water. The analysis time of the chromium components is less than 30 min. The operational parameters for the method are described in an useful format.en
dc.description.abstractDe prestaties en de uitvoering van de valentie specifieke analyse van chroom in watermonsters wordt in dit rapport beschreven. Een geautomatiseerde ionchromatografische methode voor de gelijktijdige bepaling van lage gehalten chroom(III) en chroom(IV) in diverse typen water is ontwikkeld en geoptimaliseerd. De scheiding werd verricht met een gemengde anion- en kationwisselaarskolom van Dionex, type CS5A. Hoge gevoeligheid werd bereikt met een voorconcentrering van 6 ml monster via twee CG5A guardkolommen en met een na-kolom reactie, gebaseerd op de katalystische oxidatie van luminol, met chemilumenescentie als detectie. De aantoonbaarheidsgrenzen voor chroom(VI) in Milli-Q water werd vastgesteld en bedraagt 20 ng/l. Voor chroom(III) is dit 90 ng/l. De resolutie tussen chroom(III) en chroom(VI) is uitstekend en bedraagt 10. De methode is getest voor de toepassing van drink-, regen-, grond- en oppervlakte water. De totale duur van de analyse van de beide componenten bedraagt minder dan 30 minuten. De operationele parameters van de methode zijn in een direct bruikbaar formaat in dit rapport opgenomen.nl
dc.format.extent1804000 bytesen_US
dc.format.extent1846729 bytes-
dc.format.mimetypeapplication/pdf-
dc.language.isonlen_US
dc.publisherRijksinstituut voor Volksgezondheid en Milieu RIVMen_US
dc.relation.ispartofseriesRIVM Rapport 703713006en_US
dc.relation.urlhttp://www.rivm.nl/bibliotheek/rapporten/703713006.htmlen_US
dc.titleEen ionchromatografische methode voor de bepaling van chroom(III) en chroom(IV) in drink-, grond-, regen-, en oppervlaktewater in het lage picomolbereiken_US
dc.title.alternativeAn ion chromatographic method for the determination of chromium(III) and chromium (IV)in drinking water, rainwater ground and surfacewater in the low picomol rangeen_US
dc.contributor.departmentLACen_US
All Items in WARP are protected by copyright, with all rights reserved, unless otherwise indicated.