Overzicht van onderzoek naar automatische meetmethoden voor het vaststellen van fijn stof

2.50
Hdl Handle:
http://hdl.handle.net/10029/16419
Title:
Overzicht van onderzoek naar automatische meetmethoden voor het vaststellen van fijn stof
Authors:
Arkel FT van; Kummu PJ; Loon JPL van; Meulen A van der; Severijnen M; Visser JH
Other Titles:
Review of research on automised monitoring techniques for the assessment of particulate matter
Abstract:
This report describes studies on current techniques for determining the concentration of the fine fraction (PM2.5) of particulate matter in the troposphere. The performance of the sampling technology for PM2.5 was investigated by means of a literature study based on a selection of publications (after 2000) comparing the automatic sampler method with the reference method. It was the express wish of the concerned authorities to investigate the performance of the PM2.5 methods and to harmonize measurement methodology. A careful selection of PM2.5-samplers is important if the PM2,5 methodology is to be improved. This meant considering at least the method's principle, the range of application, the effect of different configurations, effects of varied ambient conditions and uncertainties. The study's purpose was to facilitate the assessment of both the PM2.5 measurement method performance and the process of harmonization and/or normalization.; Dit rapport beschrijft de 'stand der techniek' van meetmethoden voor het vaststellen van de concentratie zwevende deeltjes in de troposfeer, gericht op de fijne fractie, de zogenaamde PM2,5-fractie. De beschrijving van de prestaties van de meetmethoden volgens de huidige stand van de techniek is gebaseerd op een literatuurstudie en op eigen ervaringen van de deelnemende instituten. De studie richt zich op de vergelijkbaarheid van de automatische meetmethoden met de standaardmethode (referentie). Het is de wens van de betrokken meetinstanties om de ervaringen met PM2,5-meetmethoden te inventariseren en om onderling de meetstrategie af te stemmen. Een zorgvuldige selectie van een PM2,5-meetmethode is daarbij van belang. Doel van het rapport is de betrokken meetinstanties te ondersteunen met een overzicht van de prestaties van verschillende meetmethoden. Daarnaast draagt het rapport bij tot het proces van normaliseren en/of harmoniseren van meetmethoden.
Other Contributors:
DCMR Milieudienst Rijnmond; GGD Amsterdam Medische Milieukunde, Luchtonderzoek; Provincie Noord-Brabant; Provincie Limburg
Affiliation:
LVM
Publisher:
Rijksinstituut voor Volksgezondheid en Milieu RIVM
Issue Date:
16-Aug-2007
URI:
http://hdl.handle.net/10029/16419
Additional Links:
http://www.rivm.nl/bibliotheek/rapporten/680708004.html
Language:
nl
Series/Report no.:
RIVM rapport 680708004
Appears in Collections:
RIVM reports - old archive

Full metadata record

DC FieldValue Language
dc.contributor.authorArkel FT vanen_GB
dc.contributor.authorKummu PJen_GB
dc.contributor.authorLoon JPL vanen_GB
dc.contributor.authorMeulen A van deren_GB
dc.contributor.authorSeverijnen Men_GB
dc.contributor.authorVisser JHen_GB
dc.contributor.otherDCMR Milieudienst Rijnmonden_GB
dc.contributor.otherGGD Amsterdam Medische Milieukunde, Luchtonderzoeken_GB
dc.contributor.otherProvincie Noord-Brabanten_GB
dc.contributor.otherProvincie Limburgen_GB
dc.date.accessioned2008-01-18T16:18:53Z-
dc.date.available2008-01-18T16:18:53Z-
dc.date.issued2007-08-16en_GB
dc.identifier680708004en_GB
dc.identifier.urihttp://hdl.handle.net/10029/16419-
dc.description.abstractThis report describes studies on current techniques for determining the concentration of the fine fraction (PM2.5) of particulate matter in the troposphere. The performance of the sampling technology for PM2.5 was investigated by means of a literature study based on a selection of publications (after 2000) comparing the automatic sampler method with the reference method. It was the express wish of the concerned authorities to investigate the performance of the PM2.5 methods and to harmonize measurement methodology. A careful selection of PM2.5-samplers is important if the PM2,5 methodology is to be improved. This meant considering at least the method's principle, the range of application, the effect of different configurations, effects of varied ambient conditions and uncertainties. The study's purpose was to facilitate the assessment of both the PM2.5 measurement method performance and the process of harmonization and/or normalization.en
dc.description.abstractDit rapport beschrijft de 'stand der techniek' van meetmethoden voor het vaststellen van de concentratie zwevende deeltjes in de troposfeer, gericht op de fijne fractie, de zogenaamde PM2,5-fractie. De beschrijving van de prestaties van de meetmethoden volgens de huidige stand van de techniek is gebaseerd op een literatuurstudie en op eigen ervaringen van de deelnemende instituten. De studie richt zich op de vergelijkbaarheid van de automatische meetmethoden met de standaardmethode (referentie). Het is de wens van de betrokken meetinstanties om de ervaringen met PM2,5-meetmethoden te inventariseren en om onderling de meetstrategie af te stemmen. Een zorgvuldige selectie van een PM2,5-meetmethode is daarbij van belang. Doel van het rapport is de betrokken meetinstanties te ondersteunen met een overzicht van de prestaties van verschillende meetmethoden. Daarnaast draagt het rapport bij tot het proces van normaliseren en/of harmoniseren van meetmethoden.nl
dc.format.extent377000 bytesen_GB
dc.language.isonlen_GB
dc.publisherRijksinstituut voor Volksgezondheid en Milieu RIVMen_GB
dc.relation.ispartofseriesRIVM rapport 680708004en_GB
dc.relation.urlhttp://www.rivm.nl/bibliotheek/rapporten/680708004.htmlen_GB
dc.subject.otheraerosolsen
dc.subject.othermeasuring methodsen
dc.subject.otherinventoryen
dc.subject.othermonitoringen
dc.subject.otherparticulate matter pm2.5en
dc.subject.otherreferenceen
dc.subject.otherperformanceen
dc.subject.otherequivalenceen
dc.subject.othercalibrationen
dc.subject.otheraerosolennl
dc.subject.otherinventarisatienl
dc.subject.othermeetmethodennl
dc.subject.otherinventarisatienl
dc.subject.othermonitoringnl
dc.subject.otherfijn stofnl
dc.subject.otherpm2,5nl
dc.subject.otherreferentienl
dc.subject.othervergelijkbaarheidnl
dc.subject.otherkalibratienl
dc.subject.otherprestatiesnl
dc.titleOverzicht van onderzoek naar automatische meetmethoden voor het vaststellen van fijn stofen_GB
dc.title.alternativeReview of research on automised monitoring techniques for the assessment of particulate matteren_GB
dc.contributor.departmentLVMen_GB
All Items in WARP are protected by copyright, with all rights reserved, unless otherwise indicated.