Oogveiligheidsaspecten van de RIVM lidarsystemen

2.50
Hdl Handle:
http://hdl.handle.net/10029/255510
Title:
Oogveiligheidsaspecten van de RIVM lidarsystemen
Authors:
de Jonge CN; Swart DPJ
Other Titles:
Eye safety considerations of all RIVM lidar systems
Abstract:
RIVM operates several Lidar systems for atmospheric research. Lidar systems use laser radiation which can cause damage to eye or skin. This report deals with safety considerations of all RIVM Lidar systems. Safety measures and calculation of safety distances are based on the European laser radiation norm IEC 825. Outsiders as well as operators are protected in the best practically-possible way for both mobile scanning Lidar systems. For the fixed Lidar systems additional research to apply a radar system as protection is desired.<br>
Publisher:
Rijksinstituut voor Volksgezondheid en Milieu RIVM
Issue Date:
31-Oct-1991
URI:
http://hdl.handle.net/10029/255510
Additional Links:
http://www.rivm.nl/bibliotheek/rapporten/222701002.html
Type:
Onderzoeksrapport
Language:
nl
Sponsors:
RIVM
Appears in Collections:
RIVM official reports

Full metadata record

DC FieldValue Language
dc.contributor.authorde Jonge CN-
dc.contributor.authorSwart DPJ-
dc.date.accessioned2012-12-12T12:04:39Z-
dc.date.available2012-12-12T12:04:39Z-
dc.date.issued1991-10-31-
dc.identifier222701002-
dc.identifier.urihttp://hdl.handle.net/10029/255510-
dc.description.abstractRIVM operates several Lidar systems for atmospheric research. Lidar systems use laser radiation which can cause damage to eye or skin. This report deals with safety considerations of all RIVM Lidar systems. Safety measures and calculation of safety distances are based on the European laser radiation norm IEC 825. Outsiders as well as operators are protected in the best practically-possible way for both mobile scanning Lidar systems. For the fixed Lidar systems additional research to apply a radar system as protection is desired.<br>en
dc.description.sponsorshipRIVM-
dc.format.extent21 p-
dc.language.isonl-
dc.publisherRijksinstituut voor Volksgezondheid en Milieu RIVM-
dc.relation.ispartofRIVM Rapport 222701002-
dc.relation.urlhttp://www.rivm.nl/bibliotheek/rapporten/222701002.html-
dc.subject15nl
dc.subject91-4nl
dc.subjectoogveiligheidnl
dc.subjectlaserstralingnl
dc.subjectlidarnl
dc.subjectveiligheidsafstand; veiligheidsmaatregelennl
dc.subjecteye safetynl
dc.subjectlaser radiationnl
dc.subjectsafety distance; safety measuresnl
dc.titleOogveiligheidsaspecten van de RIVM lidarsystemennl
dc.title.alternativeEye safety considerations of all RIVM lidar systemsen
dc.typeOnderzoeksrapport-
dc.date.updated2012-12-12T12:04:39Z-
All Items in WARP are protected by copyright, with all rights reserved, unless otherwise indicated.