Dioxines bij de sinterfabriek van Hoogovens

2.50
Hdl Handle:
http://hdl.handle.net/10029/255942
Title:
Dioxines bij de sinterfabriek van Hoogovens
Authors:
Bremmer HJ; Jong APJM de; Matthijsen AJCM; Schutter MAA; Sein AA
Other Titles:
Dioxins at the sinter plant of Hoogovens
Abstract:
Abstract niet beschikbaar

Emission measurements at the sinter plant of Hoogovens at IJmuiden show an average dioxin concentration in the stack gas of circa 2,8 ng TEQ/Nm3 (dry). The yearly emission of dioxins from this installation is estimated at 24 g TEQ. According to dispersion model calculations this emission results in a yearly mean deposition of circa 1,2 ng TEQ/(m2*year) over an area of 20x20 km2 with a maximum of 6,2 ng TEQ/(m2*year) at circa 700 m North-East of the installation. There are no cows grazing in the vicinity of the deposition maximum. Dioxin levels in cow's milk from dairy farms 6-10 km North-East of Hoogovens ranged from 0.8 to 1.4 pg TEQ/g milk fat (n=4). The dioxin level in soil from a pasture 6 km North-East from Hoogovens was 2,6 ng TEQ/kg dry soil. The deposition of dioxins, the dioxin levels in cow's milk and in soil in the vicinity of Hoogovens are not enhanced with respect to the average background levels in the Netherlands.
Issue Date:
30-Jun-1991
URI:
http://hdl.handle.net/10029/255942
Additional Links:
http://www.rivm.nl/bibliotheek/rapporten/730501022.html
Type:
Onderzoeksrapport
Language:
nl
Sponsors:
HIMH
Appears in Collections:
RIVM official reports

Full metadata record

DC FieldValue Language
dc.contributor.authorBremmer HJ-
dc.contributor.authorJong APJM de-
dc.contributor.authorMatthijsen AJCM-
dc.contributor.authorSchutter MAA-
dc.contributor.authorSein AA-
dc.date.accessioned2012-12-12T12:50:16Z-
dc.date.available2012-12-12T12:50:16Z-
dc.date.issued1991-06-30-
dc.identifier730501022-
dc.identifier.urihttp://hdl.handle.net/10029/255942-
dc.description.abstractAbstract niet beschikbaarnl
dc.description.abstractEmission measurements at the sinter plant of Hoogovens at IJmuiden show an average dioxin concentration in the stack gas of circa 2,8 ng TEQ/Nm3 (dry). The yearly emission of dioxins from this installation is estimated at 24 g TEQ. According to dispersion model calculations this emission results in a yearly mean deposition of circa 1,2 ng TEQ/(m2*year) over an area of 20x20 km2 with a maximum of 6,2 ng TEQ/(m2*year) at circa 700 m North-East of the installation. There are no cows grazing in the vicinity of the deposition maximum. Dioxin levels in cow's milk from dairy farms 6-10 km North-East of Hoogovens ranged from 0.8 to 1.4 pg TEQ/g milk fat (n=4). The dioxin level in soil from a pasture 6 km North-East from Hoogovens was 2,6 ng TEQ/kg dry soil. The deposition of dioxins, the dioxin levels in cow's milk and in soil in the vicinity of Hoogovens are not enhanced with respect to the average background levels in the Netherlands.en
dc.description.sponsorshipHIMH-
dc.format.extent27 p-
dc.language.isonl-
dc.relation.ispartofRIVM Rapport 730501022-
dc.relation.urlhttp://www.rivm.nl/bibliotheek/rapporten/730501022.html-
dc.subject17nl
dc.subject91-3nl
dc.subjectsinterfabrieknl
dc.subjectemissiesnl
dc.subjectdioxines pcdd/pcdfnl
dc.subjectsinter plant; emissionsnl
dc.subjectdioxinsnl
dc.subject914nl
dc.titleDioxines bij de sinterfabriek van Hoogovensnl
dc.title.alternativeDioxins at the sinter plant of Hoogovensen
dc.typeOnderzoeksrapport-
dc.date.updated2012-12-12T12:50:17Z-
All Items in WARP are protected by copyright, with all rights reserved, unless otherwise indicated.