De ICRU dosisequivalent grootheden in de stralingshygiene

2.50
Hdl Handle:
http://hdl.handle.net/10029/256412
Title:
De ICRU dosisequivalent grootheden in de stralingshygiene
Authors:
Grimbergen TWM
Other Titles:
The ICRU Dose Equivalent Quantities in Radiation Protection
Abstract:
Abstract niet beschikbaar

The definitions and application of the new ICRU radiation protection quantities have been reviewed and studied in literature. Special emphasis was laid on the consequences of the use of the new quantities by personnel dosimetry services, and on the consequences of the use of the new quantities during an intercomparison programme for dosimetry services. The study shows that the recommendations of the ICRU are not yet complete and not fully realizable. This means that the dosimetry services always have to make certain approximations, when they use the new quantities. In literature, several approaches have been proposed. The feasibility of an approach depends on the characteristics of the dosimeters used. The use of different approaches by the dosimetry services is thought to be of possible influence on the results of an intercomparison programme.
Issue Date:
30-Sep-1990
URI:
http://hdl.handle.net/10029/256412
Additional Links:
http://www.rivm.nl/bibliotheek/rapporten/243506001.html
Type:
Onderzoeksrapport
Language:
nl
Sponsors:
SZW/DGA
Appears in Collections:
RIVM official reports

Full metadata record

DC FieldValue Language
dc.contributor.authorGrimbergen TWM-
dc.date.accessioned2012-12-12T13:58:17Z-
dc.date.available2012-12-12T13:58:17Z-
dc.date.issued1990-09-30-
dc.identifier243506001-
dc.identifier.urihttp://hdl.handle.net/10029/256412-
dc.description.abstractAbstract niet beschikbaarnl
dc.description.abstractThe definitions and application of the new ICRU radiation protection quantities have been reviewed and studied in literature. Special emphasis was laid on the consequences of the use of the new quantities by personnel dosimetry services, and on the consequences of the use of the new quantities during an intercomparison programme for dosimetry services. The study shows that the recommendations of the ICRU are not yet complete and not fully realizable. This means that the dosimetry services always have to make certain approximations, when they use the new quantities. In literature, several approaches have been proposed. The feasibility of an approach depends on the characteristics of the dosimeters used. The use of different approaches by the dosimetry services is thought to be of possible influence on the results of an intercomparison programme.en
dc.description.sponsorshipSZW/DGA-
dc.format.extent38 p-
dc.language.isonl-
dc.relation.ispartofRIVM Rapport 243506001-
dc.relation.urlhttp://www.rivm.nl/bibliotheek/rapporten/243506001.html-
dc.subject16nl
dc.subjectstralingshygienenl
dc.subjectgrootheidnl
dc.subjectcalibratienl
dc.subjectdosisequivalentnl
dc.subjecticru; vergelijkingnl
dc.titleDe ICRU dosisequivalent grootheden in de stralingshygienenl
dc.title.alternativeThe ICRU Dose Equivalent Quantities in Radiation Protectionen
dc.typeOnderzoeksrapport-
dc.date.updated2012-12-12T13:58:18Z-
All Items in WARP are protected by copyright, with all rights reserved, unless otherwise indicated.