The Sixth EULEP X-ray dosimetry intercomparison

2.50
Hdl Handle:
http://hdl.handle.net/10029/256831
Title:
The Sixth EULEP X-ray dosimetry intercomparison
Authors:
Aalbers AHL; Bader FJM
Other Titles:
De 6e EULEP dosimetrievergelijking
Abstract:
Abstract niet beschikbaar

During the period March through October 1989, the Sixth EULEP X-ray Dosimetry Intercomparison on whole-body irradiation on mice was performed. The intercomparison consisted of two irradiation series; the initial study comprised 15 participating institutes, the second series were performed for 7 institutes which showed appreciable deviation from the reference value. The participants performed irradiations of mouse phantoms containing TL dosemeters. The read-out and evaluation of the TL dosemeters were perfomed at RIVM. The accuracy and precision of the dosimetry can be considered satisfactory for most of the participants. Deviations observed at several institutes indicate the need for site-visits to trace probable systematic errors.
Issue Date:
31-Mar-1991
URI:
http://hdl.handle.net/10029/256831
Additional Links:
http://www.rivm.nl/bibliotheek/rapporten/249108001.html
Type:
Onderzoeksrapport
Language:
en
Sponsors:
TNO/ITRI
Appears in Collections:
RIVM official reports

Full metadata record

DC FieldValue Language
dc.contributor.authorAalbers AHL-
dc.contributor.authorBader FJM-
dc.date.accessioned2012-12-12T14:38:02Z-
dc.date.available2012-12-12T14:38:02Z-
dc.date.issued1991-03-31-
dc.identifier249108001-
dc.identifier.urihttp://hdl.handle.net/10029/256831-
dc.description.abstractAbstract niet beschikbaarnl
dc.description.abstractDuring the period March through October 1989, the Sixth EULEP X-ray Dosimetry Intercomparison on whole-body irradiation on mice was performed. The intercomparison consisted of two irradiation series; the initial study comprised 15 participating institutes, the second series were performed for 7 institutes which showed appreciable deviation from the reference value. The participants performed irradiations of mouse phantoms containing TL dosemeters. The read-out and evaluation of the TL dosemeters were perfomed at RIVM. The accuracy and precision of the dosimetry can be considered satisfactory for most of the participants. Deviations observed at several institutes indicate the need for site-visits to trace probable systematic errors.en
dc.description.sponsorshipTNO/ITRI-
dc.format.extent35 p-
dc.language.isoen-
dc.relation.ispartofRIVM Rapport 249108001-
dc.relation.urlhttp://www.rivm.nl/bibliotheek/rapporten/249108001.html-
dc.subject16nl
dc.subject91-2nl
dc.subjectrontgenstralendosimetersnl
dc.subjecteulepnl
dc.subjectx-raysnl
dc.subjectdosimetry; intercomparisonnl
dc.subjecttld;nl
dc.titleThe Sixth EULEP X-ray dosimetry intercomparisonen
dc.title.alternativeDe 6e EULEP dosimetrievergelijkingnl
dc.typeOnderzoeksrapport-
dc.date.updated2012-12-12T14:38:03Z-
All Items in WARP are protected by copyright, with all rights reserved, unless otherwise indicated.