De eerste nationale vergelijking van erkende diensten voor persoonsdosimetrie in Nederland

2.50
Hdl Handle:
http://hdl.handle.net/10029/257383
Title:
De eerste nationale vergelijking van erkende diensten voor persoonsdosimetrie in Nederland
Authors:
Grimbergen TWM
Other Titles:
First National Intercomparison for Individual Monitoring Services in the Netherlands
Abstract:
Abstract niet beschikbaar

In 1990, an intercomparison programme for personnel dosimetry services was developed and carried out by the National Institute of Public Health and Environmental Protection. Six services participated in this first national intercomparison in the Netherlands, all using TLD systems. In addition, one service also participated with a film badge system. The dosemeters were irradiated with photons on the surface of a 30 cm diameter sphere of polymethylmethacrylate (PMMA). The range of the mean photon energy was 48 keV to 1250 keV. The range of the doses was 0.055 mSv to 12.3 mSv. All services were able to reproduce doses larger than 0.2 mSv within -33% and +50%. For doses smaller than 0.2 mSv all services using TLD systems were able to reproduce the conventional true value within +- 100%.
Issue Date:
30-Apr-1991
URI:
http://hdl.handle.net/10029/257383
Additional Links:
http://www.rivm.nl/bibliotheek/rapporten/243506002.html
Type:
Onderzoeksrapport
Language:
nl
Sponsors:
SZW/DGA
Appears in Collections:
RIVM official reports

Full metadata record

DC FieldValue Language
dc.contributor.authorGrimbergen TWM-
dc.date.accessioned2012-12-12T15:31:08Z-
dc.date.available2012-12-12T15:31:08Z-
dc.date.issued1991-04-30-
dc.identifier243506002-
dc.identifier.urihttp://hdl.handle.net/10029/257383-
dc.description.abstractAbstract niet beschikbaarnl
dc.description.abstractIn 1990, an intercomparison programme for personnel dosimetry services was developed and carried out by the National Institute of Public Health and Environmental Protection. Six services participated in this first national intercomparison in the Netherlands, all using TLD systems. In addition, one service also participated with a film badge system. The dosemeters were irradiated with photons on the surface of a 30 cm diameter sphere of polymethylmethacrylate (PMMA). The range of the mean photon energy was 48 keV to 1250 keV. The range of the doses was 0.055 mSv to 12.3 mSv. All services were able to reproduce doses larger than 0.2 mSv within -33% and +50%. For doses smaller than 0.2 mSv all services using TLD systems were able to reproduce the conventional true value within +- 100%.en
dc.description.sponsorshipSZW/DGA-
dc.format.extent54 p-
dc.language.isonl-
dc.relation.ispartofRIVM Rapport 243506002-
dc.relation.urlhttp://www.rivm.nl/bibliotheek/rapporten/243506002.html-
dc.subject16nl
dc.subject91-2nl
dc.subjectvergelijkingnl
dc.subjectpersoonsdosimetrienl
dc.subjectpersonnel dosimetrynl
dc.subjecttld; intercomparisonnl
dc.titleDe eerste nationale vergelijking van erkende diensten voor persoonsdosimetrie in Nederlandnl
dc.title.alternativeFirst National Intercomparison for Individual Monitoring Services in the Netherlandsen
dc.typeOnderzoeksrapport-
dc.date.updated2012-12-12T15:31:08Z-
All Items in WARP are protected by copyright, with all rights reserved, unless otherwise indicated.