First ISNS Reference Preparation for Neonatal Screening for thyrotropin, phenylalanine and 17a-hydroxyprogesterone in blood spots

2.50
Hdl Handle:
http://hdl.handle.net/10029/7233
Title:
First ISNS Reference Preparation for Neonatal Screening for thyrotropin, phenylalanine and 17a-hydroxyprogesterone in blood spots
Authors:
Elvers LH; Loeber JG; Dhondt JL; Fukushi M; Hannon WH; Torresani T; Webster D
Other Titles:
Het eerste ISNS Referentie Preparaat voor Neonatale Screening op thyrotropine, fenylalanine en 17a-hydroxyprogesteron in bloedvlekken
Abstract:
Many countries have a screening programme for newborns for congenital metabolic disorders. For this screening several components are measured in dried blood spots collected by a heel stick on filter paper. Most laboratories use commercially available reagent sets for the measurements. Manufacturers of these reagents often calibrate their reagent sets against own calibrators. Moreover several types of filter paper, each with different specifications are in use all over the world. These factors make it difficult to compare results from different screening laboratories and to evaluate such screening programmes. In the past the International Society for Neonatal Screening (ISNS) has been able to persuade manufacturers to use previously prepared dried blood spot reference materials as calibration standards. Having run out of stock, in 2004 the ISNS asked the RIVM to produce a combined reference preparation in filter paper blood with known concentrations of thyrotropine, 17alpha-hydroxyprogesterone and phenylalanine, being the markers of interest for screening on disorders of the thyroid gland, the adrenal gland and amino acid metabolism, respectively. This report describes the production and evaluation of this reference preparation.; Bij screening van pasgeborenen voor aangeboren stofwisselingsziekten wordt in een bloedmonster, verkregen via de hielprik en opgevangen op filtreerpapier, een aantal bloedcomponenten gemeten. Veelal wordt gebruik gemaakt van commercieel verkrijgbare reagentia sets. De fabrikanten kalibreren hun reagentia sets vaak met hun eigen kalibratoren. Bovendien zijn er in de wereld meerdere filtreerpapiersoorten in gebruik, met verschillen in specificaties. Door deze beide oorzaken zijn de uitslagen van verschillende screeningslaboratoria vaak niet goed vergelijkbaar. Dit bemoeilijkt de evaluatie van zulke screeningsprogramma's. De International Society for Neonatal Screening (ISNS) heeft eerder goede ervaringen opgedaan met het laten bereiden van referentiematerialen in filtreerpapierbloed en het overreden van fabrikanten om deze materialen te gebruiken als maatstaf. In 2004 heeft de ISNS aan het RIVM verzocht om een gecombineerd referentiemateriaal te maken voor filtreerpapierbloed met bekende concentraties aan thyrotropine, 17alpha-hydroxyprogesteron, en phenylalanine, merkstoffen die van belang zijn voor de screening op stoornissen in de schildklier, bijnier, respectievelijk eiwitmetabolisme. In dit rapport is de bereiding en evaluatie van dit referentiemateriaal beschreven.
Other Contributors:
Hopital Saint Philibert, Lille, France; Sapporo City Institute of Public Health, Sapporo, Japan; Centers for Disease Control and Prevention, Atlanta, GA, USA; Universitats Kinderklinik, zurich, Switzerland; National Testing Center, Auckland, New Zealand
Affiliation:
LIS
Publisher:
Rijksinstituut voor Volksgezondheid en Milieu RIVM
Issue Date:
15-Sep-2005
URI:
http://hdl.handle.net/10029/7233
Additional Links:
http://www.rivm.nl/bibliotheek/rapporten/230011004.html
Language:
en
Series/Report no.:
RIVM rapport 230011004
Appears in Collections:
RIVM reports - old archive

Full metadata record

DC FieldValue Language
dc.contributor.authorElvers LHen_US
dc.contributor.authorLoeber JGen_US
dc.contributor.authorDhondt JLen_US
dc.contributor.authorFukushi Men_US
dc.contributor.authorHannon WHen_US
dc.contributor.authorTorresani Ten_US
dc.contributor.authorWebster Den_US
dc.contributor.otherHopital Saint Philibert, Lille, Franceen_US
dc.contributor.otherSapporo City Institute of Public Health, Sapporo, Japanen_US
dc.contributor.otherCenters for Disease Control and Prevention, Atlanta, GA, USAen_US
dc.contributor.otherUniversitats Kinderklinik, zurich, Switzerlanden_US
dc.contributor.otherNational Testing Center, Auckland, New Zealanden_US
dc.date.accessioned2007-01-11T13:17:42Z-
dc.date.available2007-01-11T13:17:42Z-
dc.date.issued2005-09-15en_US
dc.identifier230011004en_US
dc.identifier.urihttp://hdl.handle.net/10029/7233-
dc.description.abstractMany countries have a screening programme for newborns for congenital metabolic disorders. For this screening several components are measured in dried blood spots collected by a heel stick on filter paper. Most laboratories use commercially available reagent sets for the measurements. Manufacturers of these reagents often calibrate their reagent sets against own calibrators. Moreover several types of filter paper, each with different specifications are in use all over the world. These factors make it difficult to compare results from different screening laboratories and to evaluate such screening programmes. In the past the International Society for Neonatal Screening (ISNS) has been able to persuade manufacturers to use previously prepared dried blood spot reference materials as calibration standards. Having run out of stock, in 2004 the ISNS asked the RIVM to produce a combined reference preparation in filter paper blood with known concentrations of thyrotropine, 17alpha-hydroxyprogesterone and phenylalanine, being the markers of interest for screening on disorders of the thyroid gland, the adrenal gland and amino acid metabolism, respectively. This report describes the production and evaluation of this reference preparation.en
dc.description.abstractBij screening van pasgeborenen voor aangeboren stofwisselingsziekten wordt in een bloedmonster, verkregen via de hielprik en opgevangen op filtreerpapier, een aantal bloedcomponenten gemeten. Veelal wordt gebruik gemaakt van commercieel verkrijgbare reagentia sets. De fabrikanten kalibreren hun reagentia sets vaak met hun eigen kalibratoren. Bovendien zijn er in de wereld meerdere filtreerpapiersoorten in gebruik, met verschillen in specificaties. Door deze beide oorzaken zijn de uitslagen van verschillende screeningslaboratoria vaak niet goed vergelijkbaar. Dit bemoeilijkt de evaluatie van zulke screeningsprogramma's. De International Society for Neonatal Screening (ISNS) heeft eerder goede ervaringen opgedaan met het laten bereiden van referentiematerialen in filtreerpapierbloed en het overreden van fabrikanten om deze materialen te gebruiken als maatstaf. In 2004 heeft de ISNS aan het RIVM verzocht om een gecombineerd referentiemateriaal te maken voor filtreerpapierbloed met bekende concentraties aan thyrotropine, 17alpha-hydroxyprogesteron, en phenylalanine, merkstoffen die van belang zijn voor de screening op stoornissen in de schildklier, bijnier, respectievelijk eiwitmetabolisme. In dit rapport is de bereiding en evaluatie van dit referentiemateriaal beschreven.nl
dc.format.extent410000 bytesen_US
dc.format.extent420637 bytes-
dc.format.mimetypeapplication/pdf-
dc.language.isoenen_US
dc.publisherRijksinstituut voor Volksgezondheid en Milieu RIVMen_US
dc.relation.ispartofseriesRIVM rapport 230011004en_US
dc.relation.urlhttp://www.rivm.nl/bibliotheek/rapporten/230011004.htmlen_US
dc.subject.othernewbornen
dc.subject.otherscreeningen
dc.subject.othercahen
dc.subject.otherpkuen
dc.subject.otherchten
dc.subject.otherreference preparationen
dc.subject.otherpasgeborenennl
dc.subject.otherhielpriknl
dc.subject.otherscreeningnl
dc.subject.otheragsnl
dc.subject.otherpkunl
dc.subject.otherchtnl
dc.subject.otherreferentie preparaatnl
dc.titleFirst ISNS Reference Preparation for Neonatal Screening for thyrotropin, phenylalanine and 17a-hydroxyprogesterone in blood spotsen_US
dc.title.alternativeHet eerste ISNS Referentie Preparaat voor Neonatale Screening op thyrotropine, fenylalanine en 17a-hydroxyprogesteron in bloedvlekkenen_US
dc.contributor.departmentLISen_US
All Items in WARP are protected by copyright, with all rights reserved, unless otherwise indicated.