Abstract:
Most radiology departments of Dutch hospitals hold unused possibilities for lowering the radiation dose to children. This was found in an investigation commissioned to the RIVM by the Dutch Health Care Inspectorate. Since children are more sensitive to the long-term harmful effects of ionizing radiation than adults, it is important to give radiation dose in children due attention. Radiographic imaging for children requires a lower dose than for adults. When x-ray equipment optimized for adults is used for children, they receive a higher dose. The average required dose can be reduced further by using dedicated protocols.d dedicated protocols for paediatric CT and fluoroscopy to often be missing. In some cases, obsolete fluoroscopy equipment is employed. On the other hand, the CT-scanners used are relatively modern. Radiologists indicate opting whenever possible for examinations without ionizing radiation such as ultrasound and MR. Follow-up also generally takes place in specialized children's hospitals that are better equipped. The investigation was carried out by conducting an oral survey. Two academic children's hospitals were visited, along with a representative sample of eighteen general hospitals. The recommendations following the investigation were formulated in cooperation with the paediatric radiology section of the Dutch Society for Radiology (NVvR).; De stralingsdosis bij rontgenonderzoek van kinderen kan in de meeste algemene ziekenhuizen lager. Dat blijkt uit een inventarisatie van het RIVM in opdracht van de Inspectie voor de Gezondheidszorg. Aandacht voor de stralingsdosis bij kinderen is belangrijk. Kinderen zijn namelijk gevoeliger voor de schadelijke effecten van straling op lange termijn dan volwassenen. Voor een goede rontgenafbeelding van een kind volstaat een lagere dosis straling. Wanneer een kind wordt onderzocht met rontgenapparatuur die is afgesteld op een volwassene, krijgt het een hogere dosis straling dan een volwassene. Door speciale protocollen op te stellen voor rontgenonderzoek van kinderen kan de stralingsdosis beter worden beperkt. Uit de inventarisatie van het RIVM bleek dat aanbevolen voorzieningen en speciale protocollen voor CT en doorlichting van kinderen en baby's vaak ontbreken. Voor doorlichting wordt soms verouderde apparatuur gebruikt. De CT-scanners zijn over het algemeen wel modern. Daarnaast kiezen radiologen waar mogelijk voor onderzoek zonder ioniserende straling, zoals een echo of MRI-scan. Ook vindt vervolgonderzoek vrijwel altijd plaats in gespecialiseerde kinderziekenhuizen, met beter aangepaste apparatuur. De inventarisatie is gedaan door middel van een mondelinge enquete. Er zijn twee academische kinderziekenhuizen bezocht en er is een representatieve steekproef gedaan van achttien algemene ziekenhuizen. De aanbevelingen naar aanleiding van het onderzoek zijn geformuleerd in samenwerking met de sectie kinderradiologie van de Nederlandse Vereniging voor Radiologie.
Affiliation:
LSO
Publisher:
Rijksinstituut voor Volksgezondheid en Milieu RIVM
Issue Date:
6-Nov-2006
URI:
http://hdl.handle.net/10029/7270
Additional Links:
http://www.rivm.nl/bibliotheek/rapporten/265021005.html
Language:
nl
Series/Report no.:
RIVM rapport 265021005
Appears in Collections:
RIVM reports - old archive

Full metadata record

DC FieldValue Language
dc.contributor.authorStoop Pen_US
dc.contributor.authorBijwaard Hen_US
dc.date.accessioned2007-01-12T14:49:22Z-
dc.date.available2007-01-12T14:49:22Z-
dc.date.issued2006-11-06en_US
dc.identifier265021005en_US
dc.identifier.urihttp://hdl.handle.net/10029/7270-
dc.description.abstractMost radiology departments of Dutch hospitals hold unused possibilities for lowering the radiation dose to children. This was found in an investigation commissioned to the RIVM by the Dutch Health Care Inspectorate. Since children are more sensitive to the long-term harmful effects of ionizing radiation than adults, it is important to give radiation dose in children due attention. Radiographic imaging for children requires a lower dose than for adults. When x-ray equipment optimized for adults is used for children, they receive a higher dose. The average required dose can be reduced further by using dedicated protocols.d dedicated protocols for paediatric CT and fluoroscopy to often be missing. In some cases, obsolete fluoroscopy equipment is employed. On the other hand, the CT-scanners used are relatively modern. Radiologists indicate opting whenever possible for examinations without ionizing radiation such as ultrasound and MR. Follow-up also generally takes place in specialized children's hospitals that are better equipped. The investigation was carried out by conducting an oral survey. Two academic children's hospitals were visited, along with a representative sample of eighteen general hospitals. The recommendations following the investigation were formulated in cooperation with the paediatric radiology section of the Dutch Society for Radiology (NVvR).en
dc.description.abstractDe stralingsdosis bij rontgenonderzoek van kinderen kan in de meeste algemene ziekenhuizen lager. Dat blijkt uit een inventarisatie van het RIVM in opdracht van de Inspectie voor de Gezondheidszorg. Aandacht voor de stralingsdosis bij kinderen is belangrijk. Kinderen zijn namelijk gevoeliger voor de schadelijke effecten van straling op lange termijn dan volwassenen. Voor een goede rontgenafbeelding van een kind volstaat een lagere dosis straling. Wanneer een kind wordt onderzocht met rontgenapparatuur die is afgesteld op een volwassene, krijgt het een hogere dosis straling dan een volwassene. Door speciale protocollen op te stellen voor rontgenonderzoek van kinderen kan de stralingsdosis beter worden beperkt. Uit de inventarisatie van het RIVM bleek dat aanbevolen voorzieningen en speciale protocollen voor CT en doorlichting van kinderen en baby's vaak ontbreken. Voor doorlichting wordt soms verouderde apparatuur gebruikt. De CT-scanners zijn over het algemeen wel modern. Daarnaast kiezen radiologen waar mogelijk voor onderzoek zonder ioniserende straling, zoals een echo of MRI-scan. Ook vindt vervolgonderzoek vrijwel altijd plaats in gespecialiseerde kinderziekenhuizen, met beter aangepaste apparatuur. De inventarisatie is gedaan door middel van een mondelinge enquete. Er zijn twee academische kinderziekenhuizen bezocht en er is een representatieve steekproef gedaan van achttien algemene ziekenhuizen. De aanbevelingen naar aanleiding van het onderzoek zijn geformuleerd in samenwerking met de sectie kinderradiologie van de Nederlandse Vereniging voor Radiologie.nl
dc.format.extent167000 bytesen_US
dc.format.extent170503 bytes-
dc.format.mimetypeapplication/pdf-
dc.language.isonlen_US
dc.publisherRijksinstituut voor Volksgezondheid en Milieu RIVMen_US
dc.relation.ispartofseriesRIVM rapport 265021005en_US
dc.relation.urlhttp://www.rivm.nl/bibliotheek/rapporten/265021005.htmlen_US
dc.subject.othercomputed tomographyen
dc.subject.otherfluoroscopyen
dc.subject.otherradiologyen
dc.subject.otherpatient safetyen
dc.subject.otherpaediatricsen
dc.subject.othercomputertomografienl
dc.subject.otherfluoroscopienl
dc.subject.otherradiodiagnostieknl
dc.subject.otherpatientveiligheidnl
dc.subject.otherkinderennl
dc.subject.otherpediatrienl
dc.titleOptimalisatie van de dosis bij radiologisch onderzoek van kinderen - Inventarisatie van de praktijk in algemene ziekenhuizenen_US
dc.title.alternativeOptimization of dose in paediatric radiological imagingen_US
dc.contributor.departmentLSOen_US
All Items in WARP are protected by copyright, with all rights reserved, unless otherwise indicated.