EU Interlaboratory comparison study VIII (2004) on bacteriological detection of Salmonella spp.

2.50
Hdl Handle:
http://hdl.handle.net/10029/7321
Title:
EU Interlaboratory comparison study VIII (2004) on bacteriological detection of Salmonella spp.
Authors:
Korver H; Heisterkamp SH; Veenman C; Mooijman KA
Other Titles:
EU Ringonderzoek VIII (2004) voor bacteriologische detectie van Salmonella spp.
Abstract:
In 2004 the eighth interlaboratory comparison study on bacteriological detection of Salmonella spp. was organized by the Community Reference Laboratory for Salmonella (CRL-Salmonella, Bilthoven, the Netherlands). National Reference Laboratories for Salmonella (NRLs-Salmonella) of the EU Member States (26), the NRL of Norway and of Romania participated in the study. Reference materials in combination with or without the presence of chicken faeces, as well as naturally contaminated faecal samples (containing Salmonella Enteritidis) were tested. The reference materials existed of gelatin capsules containing Salmonella Typhimurium (STM), Salmonella Enteritidis (SE) or Salmonella Panama (SPan) at different contamination levels. In addition to the performance testing of the laboratories, a comparison was made between 4 h and 18 h incubation of the samples in the pre-enrichment broth Buffered Peptone Water (BPW), followed by selective enrichment on Modified Semi-solid Rappaport Vassiliadis (MSRV) and plating-out on Xylose Lysine Deoxycholate agar (XLD). Significant more positive isolations were obtained from the artificially contaminated samples (negative chicken faeces, artificially contaminated with reference materials) after 18 hours of incubation in BPW. The accuracy rates for the artificially contaminated samples were 49% and 77% after respectively 4 and 18 hours of incubation in BPW. The overall results for the naturally contaminated samples revealed significant more positive results after 4 hours of incubation. The accuracy rates for these samples were respectively 81% and 56 % after 4 and 18 hours of incubation in BPW.; In 2004 werd door het Communautair Referentie Laboratorium voor Salmonella (CRL-Salmonella, Bilthoven, Nederland) het achtste bacteriologische ringonderzoek georganiseerd. Deelnemers van de studie waren de Nationale Referentie Laboratoria voor Salmonella (NRL's-Salmonella) van de EU lidstaten (26), van Noorwegen en van Roemenie. Referentiematerialen in combinatie met of zonder de aanwezigheid van kippenfeces, evenals natuurlijk besmette feces (bevattende Salmonella Enteritidis) werden getest. De referentiematerialen bestonden uit gelatine capsules met verschillende besmettingsniveaus van Salmonella Typhimurium (STM), Salmonella Enteritidis (SE) en Salmonella Panama (SPan). Bovendien werd naast de uitvoering van de testen door de laboratoria een vergelijking gemaakt tussen 4 en 18 uur voorophoping van de monsters in gebufferd Pepton Water (BPW), gevolgd door selectieve ophoping op Modified Semi-solid Rappaport Vassiliadis en uitplating op Xylose Lysine Deoxycholate agar. Significant meer positieve isolaties werden gevonden met de kunstmatig besmette monsters (negatieve kippenfeces, kunstmatig besmet met referentiematerialen) na 18 uur incubatie in BPW. De waardes voor nauwkeurigheid ("accuracy rates") van de kunstmatig besmette monsters waren 49% en 77% na respectievelijk 4 en 18 uur incubatie in BPW. De totale resultaten van de natuurlijk besmette monsters lieten significant meer positieve isolaties zien na 4 uur incubatie. De waardes voor nauwkeurigheid ("accuracy rates") voor deze monsters waren respectievelijk 81% en 56% na 4 en 18 uur incubatie in BPW.
Affiliation:
MGB
Publisher:
Rijksinstituut voor Volksgezondheid en Milieu RIVM
Issue Date:
24-Feb-2006
URI:
http://hdl.handle.net/10029/7321
Additional Links:
http://www.rivm.nl/bibliotheek/rapporten/330300008.html
Language:
en
Series/Report no.:
RIVM rapport 330300008
Appears in Collections:
RIVM reports - old archive

Full metadata record

DC FieldValue Language
dc.contributor.authorKorver Hen_US
dc.contributor.authorHeisterkamp SHen_US
dc.contributor.authorVeenman Cen_US
dc.contributor.authorMooijman KAen_US
dc.date.accessioned2007-01-12T14:51:55Z-
dc.date.available2007-01-12T14:51:55Z-
dc.date.issued2006-02-24en_US
dc.identifier330300008en_US
dc.identifier.urihttp://hdl.handle.net/10029/7321-
dc.description.abstractIn 2004 the eighth interlaboratory comparison study on bacteriological detection of Salmonella spp. was organized by the Community Reference Laboratory for Salmonella (CRL-Salmonella, Bilthoven, the Netherlands). National Reference Laboratories for Salmonella (NRLs-Salmonella) of the EU Member States (26), the NRL of Norway and of Romania participated in the study. Reference materials in combination with or without the presence of chicken faeces, as well as naturally contaminated faecal samples (containing Salmonella Enteritidis) were tested. The reference materials existed of gelatin capsules containing Salmonella Typhimurium (STM), Salmonella Enteritidis (SE) or Salmonella Panama (SPan) at different contamination levels. In addition to the performance testing of the laboratories, a comparison was made between 4 h and 18 h incubation of the samples in the pre-enrichment broth Buffered Peptone Water (BPW), followed by selective enrichment on Modified Semi-solid Rappaport Vassiliadis (MSRV) and plating-out on Xylose Lysine Deoxycholate agar (XLD). Significant more positive isolations were obtained from the artificially contaminated samples (negative chicken faeces, artificially contaminated with reference materials) after 18 hours of incubation in BPW. The accuracy rates for the artificially contaminated samples were 49% and 77% after respectively 4 and 18 hours of incubation in BPW. The overall results for the naturally contaminated samples revealed significant more positive results after 4 hours of incubation. The accuracy rates for these samples were respectively 81% and 56 % after 4 and 18 hours of incubation in BPW.en
dc.description.abstractIn 2004 werd door het Communautair Referentie Laboratorium voor Salmonella (CRL-Salmonella, Bilthoven, Nederland) het achtste bacteriologische ringonderzoek georganiseerd. Deelnemers van de studie waren de Nationale Referentie Laboratoria voor Salmonella (NRL's-Salmonella) van de EU lidstaten (26), van Noorwegen en van Roemenie. Referentiematerialen in combinatie met of zonder de aanwezigheid van kippenfeces, evenals natuurlijk besmette feces (bevattende Salmonella Enteritidis) werden getest. De referentiematerialen bestonden uit gelatine capsules met verschillende besmettingsniveaus van Salmonella Typhimurium (STM), Salmonella Enteritidis (SE) en Salmonella Panama (SPan). Bovendien werd naast de uitvoering van de testen door de laboratoria een vergelijking gemaakt tussen 4 en 18 uur voorophoping van de monsters in gebufferd Pepton Water (BPW), gevolgd door selectieve ophoping op Modified Semi-solid Rappaport Vassiliadis en uitplating op Xylose Lysine Deoxycholate agar. Significant meer positieve isolaties werden gevonden met de kunstmatig besmette monsters (negatieve kippenfeces, kunstmatig besmet met referentiematerialen) na 18 uur incubatie in BPW. De waardes voor nauwkeurigheid ("accuracy rates") van de kunstmatig besmette monsters waren 49% en 77% na respectievelijk 4 en 18 uur incubatie in BPW. De totale resultaten van de natuurlijk besmette monsters lieten significant meer positieve isolaties zien na 4 uur incubatie. De waardes voor nauwkeurigheid ("accuracy rates") voor deze monsters waren respectievelijk 81% en 56% na 4 en 18 uur incubatie in BPW.nl
dc.format.extent801000 bytesen_US
dc.format.extent819762 bytes-
dc.format.mimetypeapplication/pdf-
dc.language.isoenen_US
dc.publisherRijksinstituut voor Volksgezondheid en Milieu RIVMen_US
dc.relation.ispartofseriesRIVM rapport 330300008en_US
dc.relation.urlhttp://www.rivm.nl/bibliotheek/rapporten/330300008.htmlen_US
dc.subject.othercrl-salmonellaen
dc.subject.othersalmonellaen
dc.subject.otherinterlaboratory comparisonen
dc.subject.otherreference materialsen
dc.subject.otherdetection methodsen
dc.subject.othercrl-salmonellanl
dc.subject.othersalmonellanl
dc.subject.otherringonderzoeknl
dc.subject.otherreferentie materialennl
dc.subject.otherdetectie methodennl
dc.titleEU Interlaboratory comparison study VIII (2004) on bacteriological detection of Salmonella spp.en_US
dc.title.alternativeEU Ringonderzoek VIII (2004) voor bacteriologische detectie van Salmonella spp.en_US
dc.contributor.departmentMGBen_US
All Items in WARP are protected by copyright, with all rights reserved, unless otherwise indicated.