Overzicht van onderzoek naar correctiefactoren voor automatische PM10 metingen in Nederland

2.50
Hdl Handle:
http://hdl.handle.net/10029/7426
Title:
Overzicht van onderzoek naar correctiefactoren voor automatische PM10 metingen in Nederland
Authors:
Jonge D de; Meulen A van der; Elshout S van den; Laan J van der; Kummu P; Visser J; Weijers E; Loon J van; Severijnen M
Other Titles:
Overview of research on correction factors for automated PM10 measurements in the Netherlands
Abstract:
PM10 measurements are complicated. The automated monitors, which are used to measure the PM10 concentration in ambient air, show an underestimation in relation to the reference method.This report contains an overview of research on the correction factors for automated PM10 measurements by DCMR, GGD Amsterdam, Provincie Noord-Brabant, Provincie Limburg and RIVM.To improve the quality and comparability of the various factors, it is of main concern to further harmonise the research in the Netherlands on this area. This report is the beginning of this process. Continuation of this research is needed.

PM10 metingen zijn niet eenvoudig. De automatische meetapparatuur die wordt toegepast om de concentratie PM10 in de buitenlucht te bepalen, geeft een onderschatting ten opzichte van de gravimetrische referentiemethode volgens NEN EN 12341. Dit heeft te maken met de aanwezigheid van vluchtige componenten in fijn stof. Dit rapport bevat een overzicht van de onderzoeken naar de correctiefactoren voor automatische PM10 metingen door DCMR, GGD Amsterdam, Provincie Noord-Brabant, Provincie Limburg en het RIVM in de afgelopen jaren.Om de kwaliteit, en vergelijkbaarheid, van de verschillende factoren te verbeteren is het van belang de verschillende onderzoeken die op dit gebied binnen Nederland worden uitgevoerd verder te harmoniseren.
Other Contributors:
DCMR; GGD Amsterdam; Provincie Noord-Brabant; Provincie Limburg
Affiliation:
MEV-LVM
Publisher:
Rijksinstituut voor Volksgezondheid en Milieu RIVM
Issue Date:
31-Jan-2006
URI:
http://hdl.handle.net/10029/7426
Additional Links:
http://www.rivm.nl/bibliotheek/rapporten/680500002.html
Language:
nl
Series/Report no.:
RIVM Rapport 680500002; RIVM Rapport 680500002
Appears in Collections:
RIVM reports - old archive

Full metadata record

DC FieldValue Language
dc.contributor.authorJonge D deen_US
dc.contributor.authorMeulen A van deren_US
dc.contributor.authorElshout S van denen_US
dc.contributor.authorLaan J van deren_US
dc.contributor.authorKummu Pen_US
dc.contributor.authorVisser Jen_US
dc.contributor.authorWeijers Een_US
dc.contributor.authorLoon J vanen_US
dc.contributor.authorSeverijnen Men_US
dc.contributor.otherDCMRen_US
dc.contributor.otherGGD Amsterdamen_US
dc.contributor.otherProvincie Noord-Brabanten_US
dc.contributor.otherProvincie Limburgen_US
dc.date.accessioned2007-01-12T14:56:32Z-
dc.date.available2007-01-12T14:56:32Z-
dc.date.issued2006-01-31en_US
dc.identifier680500002en_US
dc.identifier.urihttp://hdl.handle.net/10029/7426-
dc.description.abstractPM10 measurements are complicated. The automated monitors, which are used to measure the PM10 concentration in ambient air, show an underestimation in relation to the reference method.This report contains an overview of research on the correction factors for automated PM10 measurements by DCMR, GGD Amsterdam, Provincie Noord-Brabant, Provincie Limburg and RIVM.To improve the quality and comparability of the various factors, it is of main concern to further harmonise the research in the Netherlands on this area. This report is the beginning of this process. Continuation of this research is needed.en
dc.description.abstractPM10 metingen zijn niet eenvoudig. De automatische meetapparatuur die wordt toegepast om de concentratie PM10 in de buitenlucht te bepalen, geeft een onderschatting ten opzichte van de gravimetrische referentiemethode volgens NEN EN 12341. Dit heeft te maken met de aanwezigheid van vluchtige componenten in fijn stof. Dit rapport bevat een overzicht van de onderzoeken naar de correctiefactoren voor automatische PM10 metingen door DCMR, GGD Amsterdam, Provincie Noord-Brabant, Provincie Limburg en het RIVM in de afgelopen jaren.Om de kwaliteit, en vergelijkbaarheid, van de verschillende factoren te verbeteren is het van belang de verschillende onderzoeken die op dit gebied binnen Nederland worden uitgevoerd verder te harmoniseren.nl
dc.format.extent644000 bytesen_US
dc.format.extent658514 bytes-
dc.format.mimetypeapplication/pdf-
dc.language.isonlen_US
dc.publisherRijksinstituut voor Volksgezondheid en Milieu RIVMen_US
dc.relation.ispartofseriesRIVM Rapport 680500002en_US
dc.relation.ispartofseriesRIVM Rapport 680500002-
dc.relation.urlhttp://www.rivm.nl/bibliotheek/rapporten/680500002.htmlen_US
dc.subject.othermonitoring networksen
dc.subject.otherair qualityen
dc.subject.othermeasurement equipmenten
dc.subject.othermeasuring methodsen
dc.subject.otheraerosolsen
dc.subject.otherparticulate matteren
dc.subject.othercorrection factoren
dc.subject.othernational measuring networken
dc.subject.othermeetnettennl
dc.subject.otherluchtkwaliteitnl
dc.subject.othermeetinstrumentennl
dc.subject.othermeetmethodennl
dc.subject.otheraerosolennl
dc.subject.othermetingennl
dc.subject.otherfijn stofnl
dc.subject.othercorrectiefactornl
dc.subject.otherlandelijk meetnetnl
dc.titleOverzicht van onderzoek naar correctiefactoren voor automatische PM10 metingen in Nederlanden_US
dc.title.alternativeOverview of research on correction factors for automated PM10 measurements in the Netherlandsen_US
dc.contributor.departmentMEV-LVMen_US
All Items in WARP are protected by copyright, with all rights reserved, unless otherwise indicated.