MICROCRM: Preparation and control of batches of microbiological reference materials consisting of capsules

2.50
Hdl Handle:
http://hdl.handle.net/10029/8820
Title:
MICROCRM: Preparation and control of batches of microbiological reference materials consisting of capsules
Authors:
Mooijman KA; During M; Nagelkerke NJD
Other Titles:
MICROCRM: Bereiding en controle van partijen microbiologische referentiematerialen bestaande uit capsules
Abstract:
Batches of microbiological reference materials (RMs) were prepared for performing feasibility certification studies in the European project 'MICROCRM'. Each of the three partners in the project, Institute Pasteur (Lille, Fr), the Public Health Laboratory Services, (Newcastle, UK) and the National Institute for Public Health and the Environment, (Bilthoven, NL) produced batches of one of three different types of microbiological RMs (pastilles, lenticules or capsules). Four batches of capsule RMs, each containing a different strain, were prepared at the RIVM. Each batch was tested for its homogeneity, long-term stability at storage temperature (-20 degrees C) and short-term stability at elevated temperatures (5 degrees C, 22 degrees C, 30 degrees C, and 36 degrees C). The batch of capsule RMs containing Escherichia coli was analysed using 2 different culture methods. The batch of RMs containing Enterococcus faecium was analysed using 4 different culture methods. Batches of RMs containing Clostridium perfringens and Pseudomonas aeruginosa were each analysed using one culture method. The batch of RMs containing P. aeruginosa showed poor stability at storage temperature (-20 degrees C), therefore it was decided not to use this batch for the feasibility certification studies. The quality of the three other batches of capsule RMs was sufficient to warrant use in further studies.

Ten behoeve van het Europese project 'MICROCRM' werden partijen microbiologische referentiematerialen (RMs) bereid voor het uitvoeren van haalbaarheid certificeringsstudies. De drie partners in het project, Instituut Pasteur (Lille, Fr), Public Health Laboratory Services (Newcastle, UK) en het Rijksinstituut voor Volksgezondheid en Milieu (Bilthoven, NL), produceerden elk partijen van 55n van drie verschillende typen microbiologische RMs (pastilles, lenticules of capsules). Bij het RIVM werden vier partijen capsule RMs bereid, elk met een verschillende stam. Iedere partij werd gecontroleerd op homogeniteit, lange termijn stabiliteit bij opslagtemperatuur (-20 graden C) en korte termijn stabiliteit bij verhoogde temperaturen (5 graden C, 22 graden C, 30 graden C en 36 graden C). De partij RMs met Escherichia coli werd geanalyseerd met 2 verschillende kweekmethoden. De partij RMs met Enterococcus faecium werd geanalyseerd met 4 verschillende kweekmethoden. De partijen RMs met Clostridium perfringens en Pseudomonas aeruginosa werden ieder geanalyseerd met 1 kweekmethode. De partij RMs met P. aeruginosa was weinig stabiel bij opslagtemperatuur (-20 graden C) en er werd besloten om deze partij niet te gebruiken voor de haalbaarheid certificeringsstudies. De kwaliteit van de andere partijen capsule RMs was voldoende om te gebruiken in verdere studies.
Affiliation:
MGB
Publisher:
Rijksinstituut voor Volksgezondheid en Milieu RIVM
Issue Date:
10-Oct-2003
URI:
http://hdl.handle.net/10029/8820
Additional Links:
http://www.rivm.nl/bibliotheek/rapporten/250935001.html
Language:
en
Series/Report no.:
RIVM rapport 250935001
Appears in Collections:
RIVM reports - old archive

Full metadata record

DC FieldValue Language
dc.contributor.authorMooijman KAen_US
dc.contributor.authorDuring Men_US
dc.contributor.authorNagelkerke NJDen_US
dc.date.accessioned2007-02-23T15:26:54Z-
dc.date.available2007-02-23T15:26:54Z-
dc.date.issued2003-10-10en_US
dc.identifier250935001en_US
dc.identifier.urihttp://hdl.handle.net/10029/8820-
dc.description.abstractBatches of microbiological reference materials (RMs) were prepared for performing feasibility certification studies in the European project 'MICROCRM'. Each of the three partners in the project, Institute Pasteur (Lille, Fr), the Public Health Laboratory Services, (Newcastle, UK) and the National Institute for Public Health and the Environment, (Bilthoven, NL) produced batches of one of three different types of microbiological RMs (pastilles, lenticules or capsules). Four batches of capsule RMs, each containing a different strain, were prepared at the RIVM. Each batch was tested for its homogeneity, long-term stability at storage temperature (-20 degrees C) and short-term stability at elevated temperatures (5 degrees C, 22 degrees C, 30 degrees C, and 36 degrees C). The batch of capsule RMs containing Escherichia coli was analysed using 2 different culture methods. The batch of RMs containing Enterococcus faecium was analysed using 4 different culture methods. Batches of RMs containing Clostridium perfringens and Pseudomonas aeruginosa were each analysed using one culture method. The batch of RMs containing P. aeruginosa showed poor stability at storage temperature (-20 degrees C), therefore it was decided not to use this batch for the feasibility certification studies. The quality of the three other batches of capsule RMs was sufficient to warrant use in further studies.en
dc.description.abstractTen behoeve van het Europese project 'MICROCRM' werden partijen microbiologische referentiematerialen (RMs) bereid voor het uitvoeren van haalbaarheid certificeringsstudies. De drie partners in het project, Instituut Pasteur (Lille, Fr), Public Health Laboratory Services (Newcastle, UK) en het Rijksinstituut voor Volksgezondheid en Milieu (Bilthoven, NL), produceerden elk partijen van 55n van drie verschillende typen microbiologische RMs (pastilles, lenticules of capsules). Bij het RIVM werden vier partijen capsule RMs bereid, elk met een verschillende stam. Iedere partij werd gecontroleerd op homogeniteit, lange termijn stabiliteit bij opslagtemperatuur (-20 graden C) en korte termijn stabiliteit bij verhoogde temperaturen (5 graden C, 22 graden C, 30 graden C en 36 graden C). De partij RMs met Escherichia coli werd geanalyseerd met 2 verschillende kweekmethoden. De partij RMs met Enterococcus faecium werd geanalyseerd met 4 verschillende kweekmethoden. De partijen RMs met Clostridium perfringens en Pseudomonas aeruginosa werden ieder geanalyseerd met 1 kweekmethode. De partij RMs met P. aeruginosa was weinig stabiel bij opslagtemperatuur (-20 graden C) en er werd besloten om deze partij niet te gebruiken voor de haalbaarheid certificeringsstudies. De kwaliteit van de andere partijen capsule RMs was voldoende om te gebruiken in verdere studies.nl
dc.format.extent681000 bytesen_US
dc.format.extent697015 bytes-
dc.format.mimetypeapplication/pdf-
dc.language.isoenen_US
dc.publisherRijksinstituut voor Volksgezondheid en Milieu RIVMen_US
dc.relation.ispartofseriesRIVM rapport 250935001en_US
dc.relation.urlhttp://www.rivm.nl/bibliotheek/rapporten/250935001.htmlen_US
dc.subject.othermicrobiological reference materialsen
dc.subject.otherhomogeneityen
dc.subject.otherstabilityen
dc.titleMICROCRM: Preparation and control of batches of microbiological reference materials consisting of capsulesen_US
dc.title.alternativeMICROCRM: Bereiding en controle van partijen microbiologische referentiematerialen bestaande uit capsulesen_US
dc.contributor.departmentMGBen_US
All Items in WARP are protected by copyright, with all rights reserved, unless otherwise indicated.