2.50
Hdl Handle:
http://hdl.handle.net/10029/8845
Title:
Evaluatie pilot Endogene Factoren
Authors:
Viet AL; Fiolet D; Voortman JK; Rover C de; Hanning C; Uitenbroek D; Loon AJM van
Other Titles:
Evaluation pilot Endogenous Factors
Abstract:
As a part of the project on the Local and National Monitor for Public Health several pilot studies were carried out in three Municipal Health Centres (GGDs). The first aim was to investigate the feasibility of a physical examination at the health centre in combination with a health interview (or postal survey). The second aim was to compare several endogenous factors (total- and HDL cholesterol, and glucose) measured at the health centre by means of a finger prick (capillary blood) and in a certified lab using whole venous blood. Feasibility The response to the postal survey varied between 27% and 43%. The cooperation between the health centres and the RIVM was very good. Unfortunately the devices used for blood measurements and the home trainer, used for the physical test, broke down a few times. Preparations for carrying out the pilot took a lot of time of the people at the health centre. The participants, who received the results of the physical tests along with a gift voucher, were enthusiastic about the pilot. Comparability Correlation between measurements from capillary blood and venous blood were found to be 0.86 for total- and HDL cholesterol and 0.62 for glucose. The measurements of total- and HDL cholesterol were significantly higher in capillary blood than in venous blood. The prevalence of hypercholesterolemia was twice as high in capillary blood compared with venous blood.ConclusionCombining an interview / postal survey with a physical examination is feasible. Measurements made in capillary blood are not comparable with those in a certified lab.

In het kader van het project Lokale en Nationale Monitor Volksgezondheid (Monitor VGZ) is een aantal pilots opgezet voor het meten van endogene factoren. Doel van de pilot is het bestuderen van de haalbaarheid van een te in combinatie met een lichamelijk onderzoek op de GGD en nagaan of de waarden van totaal- en HDL cholesterol en glucose volgens een vingerprik methode overeenkomen met de uitslagen afkomstig van analysetechnieken in een gecertificeerd laboratorium. Haalbaarheid: De respons voor het lichamelijk onderzoek varieerde van 27% tot 43%. De samenwerking tussen RIVM en GGD / GG&GD was goed. Er werd meestal goed ingespeeld op problemen die tijdens het veldwerk ontstonden. Helaas weigerde de apparatuur enkele malen. De voorbereiding en de uitvoering kosten veel tijd voor de co6rdinatoren van de GGD'en. Deelnemers waren positief over het onderzoek. Vergelijkbaarheid: De correlatie voor totaal- en HDL-cholesterol tussen de vingerprik methode en de veneuze bloedafname is circa 0,86. De correlatie voor glucose is lager (0,62). Het gemiddelde totaal- en HDL-cholesterolgehalte en glucose is in het bloed afkomstig van de vingerprik significant hoger dan de waarden in veneus bloed. De prevalentie van hypercholesterolemie blijkt 2 keer zo hoog te zijn volgens de vingerprik waarden in vergelijking met de veneuze bloedwaarden. Conclusie: De uitvoering van een schriftelijke / mondelinge te in combinatie met een lichamelijk onderzoek op de GGD of op een wijkpost is haalbaar. De nieuwe meetmethode om met behulp van een vingerprik het totaal- en HDL-cholesterol en glucose te bepalen is niet vergelijkbaar met de waarden die bepaald worden in veneus bloed door een gecertificeerd laboratorium.
Affiliation:
PZO; GGD Achterhoek; GGD Midden Holland; GG&GD Amsterdam
Publisher:
Rijksinstituut voor Volksgezondheid en Milieu RIVM
Issue Date:
2-Mar-2004
URI:
http://hdl.handle.net/10029/8845
Additional Links:
http://www.rivm.nl/bibliotheek/rapporten/260854006.html
Language:
nl
Series/Report no.:
RIVM rapport 260854006
Appears in Collections:
RIVM reports - old archive

Full metadata record

DC FieldValue Language
dc.contributor.authorViet ALen_US
dc.contributor.authorFiolet Den_US
dc.contributor.authorVoortman JKen_US
dc.contributor.authorRover C deen_US
dc.contributor.authorHanning Cen_US
dc.contributor.authorUitenbroek Den_US
dc.contributor.authorLoon AJM vanen_US
dc.date.accessioned2007-02-23T15:27:59Z-
dc.date.available2007-02-23T15:27:59Z-
dc.date.issued2004-03-02en_US
dc.identifier260854006en_US
dc.identifier.urihttp://hdl.handle.net/10029/8845-
dc.description.abstractAs a part of the project on the Local and National Monitor for Public Health several pilot studies were carried out in three Municipal Health Centres (GGDs). The first aim was to investigate the feasibility of a physical examination at the health centre in combination with a health interview (or postal survey). The second aim was to compare several endogenous factors (total- and HDL cholesterol, and glucose) measured at the health centre by means of a finger prick (capillary blood) and in a certified lab using whole venous blood. Feasibility The response to the postal survey varied between 27% and 43%. The cooperation between the health centres and the RIVM was very good. Unfortunately the devices used for blood measurements and the home trainer, used for the physical test, broke down a few times. Preparations for carrying out the pilot took a lot of time of the people at the health centre. The participants, who received the results of the physical tests along with a gift voucher, were enthusiastic about the pilot. Comparability Correlation between measurements from capillary blood and venous blood were found to be 0.86 for total- and HDL cholesterol and 0.62 for glucose. The measurements of total- and HDL cholesterol were significantly higher in capillary blood than in venous blood. The prevalence of hypercholesterolemia was twice as high in capillary blood compared with venous blood.ConclusionCombining an interview / postal survey with a physical examination is feasible. Measurements made in capillary blood are not comparable with those in a certified lab.en
dc.description.abstractIn het kader van het project Lokale en Nationale Monitor Volksgezondheid (Monitor VGZ) is een aantal pilots opgezet voor het meten van endogene factoren. Doel van de pilot is het bestuderen van de haalbaarheid van een te in combinatie met een lichamelijk onderzoek op de GGD en nagaan of de waarden van totaal- en HDL cholesterol en glucose volgens een vingerprik methode overeenkomen met de uitslagen afkomstig van analysetechnieken in een gecertificeerd laboratorium. Haalbaarheid: De respons voor het lichamelijk onderzoek varieerde van 27% tot 43%. De samenwerking tussen RIVM en GGD / GG&GD was goed. Er werd meestal goed ingespeeld op problemen die tijdens het veldwerk ontstonden. Helaas weigerde de apparatuur enkele malen. De voorbereiding en de uitvoering kosten veel tijd voor de co6rdinatoren van de GGD'en. Deelnemers waren positief over het onderzoek. Vergelijkbaarheid: De correlatie voor totaal- en HDL-cholesterol tussen de vingerprik methode en de veneuze bloedafname is circa 0,86. De correlatie voor glucose is lager (0,62). Het gemiddelde totaal- en HDL-cholesterolgehalte en glucose is in het bloed afkomstig van de vingerprik significant hoger dan de waarden in veneus bloed. De prevalentie van hypercholesterolemie blijkt 2 keer zo hoog te zijn volgens de vingerprik waarden in vergelijking met de veneuze bloedwaarden. Conclusie: De uitvoering van een schriftelijke / mondelinge te in combinatie met een lichamelijk onderzoek op de GGD of op een wijkpost is haalbaar. De nieuwe meetmethode om met behulp van een vingerprik het totaal- en HDL-cholesterol en glucose te bepalen is niet vergelijkbaar met de waarden die bepaald worden in veneus bloed door een gecertificeerd laboratorium.nl
dc.format.extent457000 bytesen_US
dc.format.extent467813 bytes-
dc.format.mimetypeapplication/pdf-
dc.language.isonlen_US
dc.publisherRijksinstituut voor Volksgezondheid en Milieu RIVMen_US
dc.relation.ispartofseriesRIVM rapport 260854006en_US
dc.relation.urlhttp://www.rivm.nl/bibliotheek/rapporten/260854006.htmlen_US
dc.subject.othermonitoringnl
dc.subject.otherendogene factorennl
dc.subject.othermonitor vgznl
dc.titleEvaluatie pilot Endogene Factorenen_US
dc.title.alternativeEvaluation pilot Endogenous Factorsen_US
dc.contributor.departmentPZOen_US
dc.contributor.departmentGGD Achterhoeken_US
dc.contributor.departmentGGD Midden Hollanden_US
dc.contributor.departmentGG&GD Amsterdamen_US
All Items in WARP are protected by copyright, with all rights reserved, unless otherwise indicated.