Comparison of methods for enumeration of total coliforms and Escherichia coli in water samples in the Netherlands

2.50
Hdl Handle:
http://hdl.handle.net/10029/9453
Title:
Comparison of methods for enumeration of total coliforms and Escherichia coli in water samples in the Netherlands
Authors:
Schets FM; Nobel PJ; Strating S; Mooijman KA; Engels GB; Brouwer A
Other Titles:
Vergelijking van methoden voor bepaling van het aantal bacterien van de coligroep en Escherichia coli in monsters water in Nederland
Abstract:
The new European Drinking Water Directive (December 1998) defines a reference method for estimating the concentration of coliforms and Escherichia coli in drinking water. Laboratories may use other methods, but should demonstrate that results obtained are at least as reliable as those produced with the reference methods. Three Dutch laboratories participated in a European trial, in which a protocol for comparing enumeration methods for total coliform bacteria and Escherichia coli in water samples was tested. Besides the membrane filtration method on Lactose TTC agar with Tergitol 7 (LTTC) described in ISO 9308-1, and the Colilert(R) method, the Dutch laboratories included membrane filtration methods on Laurylsulphate Agar (LSA), Chromocult(R) Coliform Agar (CCA) and the E. coli Direct Plating method. On LTTC37 significantly more total oliforms were enumerated than on LSA37; however, the LTTC method was found suitable for analysing very clean (drinking) water samples only, due to its lack of selectivity. The DP method (or Rapid Test in ISO 9308-1) is the best method for enumeration of E. coli, while the Colilert(R) method produces 12,5 % false negative E. coli results.

De nieuwe Europese Drinkwater Richtlijn (december 1998) definieert een referentiemethode voor de schatting van de concentratie bacterien van de coligroep en Escherichia coli in drinkwater. Laboratoria mogen andere methoden gebruiken, maar moeten aantonen dat de verkregen resultaten minstens zo betrouwbaar zijn als die verkregen met de referentiemethoden. Drie Nederlandse laboratoria hebben deelgenomen aan een Europees onderzoek waarin een protocol voor het vergelijken van methoden voor het bepalen van aantallen bacterien van de coligroep en Escherichia coli in monsters water werd getest. Naast de membraanfiltratie methode op Lactose TTC agar met Tergitol 7 (LTTC) beschreven in ISO 9308-1, en Colilert(R), gebruikten de Nederlandse laboratoria membraanfiltratie methoden op Laurylsulfaat Agar (LSA), Chromocult(R) Coliform Agar (CCA) en de E. coli Direct Plating methode. Op LTTC37 werden significant hogere aantallen bacterien van de coligroep gevonden dan op LSA37; LTTC was echter alleen geschikt voor het analyseren van zeer schone (drink)water monsters vanwege gebrek aan selectiviteit. De DP methode (of Rapid Test in ISO 9308-1) is de beste methode voor bepaling van E. coli. Met Colilert(R) werd 12,5 % vals negatieve resultaten voor E. coli gevonden.
Other Contributors:
Kiwa; PWN
Affiliation:
MGB
Publisher:
Rijksinstituut voor Volksgezondheid en Milieu RIVM
Issue Date:
28-May-2001
URI:
http://hdl.handle.net/10029/9453
Additional Links:
http://www.rivm.nl/bibliotheek/rapporten/289202028.html
Language:
en
Series/Report no.:
RIVM Rapport 289202028
Appears in Collections:
RIVM reports - old archive

Full metadata record

DC FieldValue Language
dc.contributor.authorSchets FMen_US
dc.contributor.authorNobel PJen_US
dc.contributor.authorStrating Sen_US
dc.contributor.authorMooijman KAen_US
dc.contributor.authorEngels GBen_US
dc.contributor.authorBrouwer Aen_US
dc.contributor.otherKiwaen_US
dc.contributor.otherPWNen_US
dc.date.accessioned2007-02-27T12:44:06Z-
dc.date.available2007-02-27T12:44:06Z-
dc.date.issued2001-05-28en_US
dc.identifier289202028en_US
dc.identifier.urihttp://hdl.handle.net/10029/9453-
dc.description.abstractThe new European Drinking Water Directive (December 1998) defines a reference method for estimating the concentration of coliforms and Escherichia coli in drinking water. Laboratories may use other methods, but should demonstrate that results obtained are at least as reliable as those produced with the reference methods. Three Dutch laboratories participated in a European trial, in which a protocol for comparing enumeration methods for total coliform bacteria and Escherichia coli in water samples was tested. Besides the membrane filtration method on Lactose TTC agar with Tergitol 7 (LTTC) described in ISO 9308-1, and the Colilert(R) method, the Dutch laboratories included membrane filtration methods on Laurylsulphate Agar (LSA), Chromocult(R) Coliform Agar (CCA) and the E. coli Direct Plating method. On LTTC37 significantly more total oliforms were enumerated than on LSA37; however, the LTTC method was found suitable for analysing very clean (drinking) water samples only, due to its lack of selectivity. The DP method (or Rapid Test in ISO 9308-1) is the best method for enumeration of E. coli, while the Colilert(R) method produces 12,5 % false negative E. coli results.en
dc.description.abstractDe nieuwe Europese Drinkwater Richtlijn (december 1998) definieert een referentiemethode voor de schatting van de concentratie bacterien van de coligroep en Escherichia coli in drinkwater. Laboratoria mogen andere methoden gebruiken, maar moeten aantonen dat de verkregen resultaten minstens zo betrouwbaar zijn als die verkregen met de referentiemethoden. Drie Nederlandse laboratoria hebben deelgenomen aan een Europees onderzoek waarin een protocol voor het vergelijken van methoden voor het bepalen van aantallen bacterien van de coligroep en Escherichia coli in monsters water werd getest. Naast de membraanfiltratie methode op Lactose TTC agar met Tergitol 7 (LTTC) beschreven in ISO 9308-1, en Colilert(R), gebruikten de Nederlandse laboratoria membraanfiltratie methoden op Laurylsulfaat Agar (LSA), Chromocult(R) Coliform Agar (CCA) en de E. coli Direct Plating methode. Op LTTC37 werden significant hogere aantallen bacterien van de coligroep gevonden dan op LSA37; LTTC was echter alleen geschikt voor het analyseren van zeer schone (drink)water monsters vanwege gebrek aan selectiviteit. De DP methode (of Rapid Test in ISO 9308-1) is de beste methode voor bepaling van E. coli. Met Colilert(R) werd 12,5 % vals negatieve resultaten voor E. coli gevonden.nl
dc.format.extent548000 bytesen_US
dc.format.extent562068 bytes-
dc.format.mimetypeapplication/pdf-
dc.language.isoenen_US
dc.publisherRijksinstituut voor Volksgezondheid en Milieu RIVMen_US
dc.relation.ispartofseriesRIVM Rapport 289202028en_US
dc.relation.urlhttp://www.rivm.nl/bibliotheek/rapporten/289202028.htmlen_US
dc.subject.othertotal coliformsen
dc.subject.othere.colien
dc.subject.otherenumeration methodsen
dc.subject.otherwater qualityen
dc.titleComparison of methods for enumeration of total coliforms and Escherichia coli in water samples in the Netherlandsen_US
dc.title.alternativeVergelijking van methoden voor bepaling van het aantal bacterien van de coligroep en Escherichia coli in monsters water in Nederlanden_US
dc.contributor.departmentMGBen_US
All Items in WARP are protected by copyright, with all rights reserved, unless otherwise indicated.