Test results of serotyping Salmonella strains in the Member States of the European Union (A collaborative study amongst the National Reference Laboratories for Salmonella)

2.50
Hdl Handle:
http://hdl.handle.net/10029/9961
Title:
Test results of serotyping Salmonella strains in the Member States of the European Union (A collaborative study amongst the National Reference Laboratories for Salmonella)
Authors:
Voogt N; Maas HME; Leeuwen WJ van; Henken AM
Other Titles:
Serotyperingsuitslagen van Salmonella stammen in de lidstaten van de Europese Unie (Een ringonderzoek met de Nationale Referentie Laboratoria voor Salmonella)
Abstract:
A second collaborative study on Salmonella serotyping was organised by the Community Reference Laboratory (CRL) for Salmonella, with participation of the National Reference Laboratories (NRLs) for Salmonella from 14 of the 15 Member States of the European Union. The objective of the study was to investigate the capacity of the NRLs for correctly identifying serovars of Salmonella enterica subsp. enterica. Twenty serovars of Salmonella enterica subsp. enterica selected by the CRL had to be examined by all NRLs according to their routine serotyping method. Thanks to the use of many frequently occurring serovars and the possibility of NRLs to send strains to another specialized laboratory, better results were obtained than for an earlier study. The incorrect detection of H antigens was the reason for most of the incorrect identifications.; Het Communautair Referentie Laboratorium (CRL) voor Salmonella heeft een ringonderzoek voor de serotypering van Salmonella georganiseerd. De Nationale Referentie Laboratoria (NRLs) voor Salmonella uit 14 van de 15 lidstaten van de Europese Unie deden aan het onderzoek mee. Het doel was te onderzoeken of de NRLs serotypen van Salmonella enterica subsp. enterica correct konden identificeren. Twintig serotypen van Salmonella enterica subsp. enterica werden door het CRL geselecteerd. Deze moesten door de NRLs met de routinematig gebruikte serotyperingsmethode worden onderzocht. Door het gebruik van veel voorkomende serotypen en de mogelijkheid voor een NRL stammen door te sturen naar een ander gespecialiseerd laboratorium, werden betere resultaten verkregen vergeleken met een eerder ringonderzoek. De reden voor de meeste incorrecte identificaties was een incorrecte detectie van H antigenen.
Affiliation:
MGB
Publisher:
Rijksinstituut voor Volksgezondheid en Milieu RIVM
Issue Date:
30-Sep-1997
URI:
http://hdl.handle.net/10029/9961
Additional Links:
http://www.rivm.nl/bibliotheek/rapporten/284500008.html
Language:
en
Series/Report no.:
RIVM rapport 284500008
Appears in Collections:
RIVM reports - old archive

Full metadata record

DC FieldValue Language
dc.contributor.authorVoogt Nen_US
dc.contributor.authorMaas HMEen_US
dc.contributor.authorLeeuwen WJ vanen_US
dc.contributor.authorHenken AMen_US
dc.date.accessioned2007-03-09T15:44:02Z-
dc.date.available2007-03-09T15:44:02Z-
dc.date.issued1997-09-30en_US
dc.identifier284500008en_US
dc.identifier.urihttp://hdl.handle.net/10029/9961-
dc.description.abstractA second collaborative study on Salmonella serotyping was organised by the Community Reference Laboratory (CRL) for Salmonella, with participation of the National Reference Laboratories (NRLs) for Salmonella from 14 of the 15 Member States of the European Union. The objective of the study was to investigate the capacity of the NRLs for correctly identifying serovars of Salmonella enterica subsp. enterica. Twenty serovars of Salmonella enterica subsp. enterica selected by the CRL had to be examined by all NRLs according to their routine serotyping method. Thanks to the use of many frequently occurring serovars and the possibility of NRLs to send strains to another specialized laboratory, better results were obtained than for an earlier study. The incorrect detection of H antigens was the reason for most of the incorrect identifications.en
dc.description.abstractHet Communautair Referentie Laboratorium (CRL) voor Salmonella heeft een ringonderzoek voor de serotypering van Salmonella georganiseerd. De Nationale Referentie Laboratoria (NRLs) voor Salmonella uit 14 van de 15 lidstaten van de Europese Unie deden aan het onderzoek mee. Het doel was te onderzoeken of de NRLs serotypen van Salmonella enterica subsp. enterica correct konden identificeren. Twintig serotypen van Salmonella enterica subsp. enterica werden door het CRL geselecteerd. Deze moesten door de NRLs met de routinematig gebruikte serotyperingsmethode worden onderzocht. Door het gebruik van veel voorkomende serotypen en de mogelijkheid voor een NRL stammen door te sturen naar een ander gespecialiseerd laboratorium, werden betere resultaten verkregen vergeleken met een eerder ringonderzoek. De reden voor de meeste incorrecte identificaties was een incorrecte detectie van H antigenen.nl
dc.format.extent897000 bytesen_US
dc.format.extent918267 bytes-
dc.format.mimetypeapplication/pdf-
dc.language.isoenen_US
dc.publisherRijksinstituut voor Volksgezondheid en Milieu RIVMen_US
dc.relation.ispartofseriesRIVM rapport 284500008en_US
dc.relation.urlhttp://www.rivm.nl/bibliotheek/rapporten/284500008.htmlen_US
dc.subject.othersecond collaborative study on serotyping of salmonellaen
dc.subject.othercrl for salmonellaen
dc.subject.othernrls for salmonellaen
dc.subject.othersalmonella enterica subsp. entericaen
dc.subject.othertweede ringonderzoek voor serotypering van salmonellanl
dc.subject.othercrl voornl
dc.subject.othersalmonellanl
dc.subject.othernrls voor salmonellanl
dc.subject.othersalmonella enterica subsp. entericanl
dc.titleTest results of serotyping Salmonella strains in the Member States of the European Union (A collaborative study amongst the National Reference Laboratories for Salmonella)en_US
dc.title.alternativeSerotyperingsuitslagen van Salmonella stammen in de lidstaten van de Europese Unie (Een ringonderzoek met de Nationale Referentie Laboratoria voor Salmonella)en_US
dc.contributor.departmentMGBen_US
All Items in WARP are protected by copyright, with all rights reserved, unless otherwise indicated.