Abstract
Dit rapport beschrijft de resultaten van het onderzoek
naar de prestatiekenmerken van een geautomatiseerde ionchromatografische
methode voor de gelijktijdige bepalingen van eerdere anionen in diverse
typen water. De micro-bore gradient methode is voorzien van een on-line
eluens generator en een microbore suppressor in de recycling mode. Onder
andere de terugvinding, de standaardafwijking van de herhaalbaarheid en de
juistheid in grond- en regenwater zijn vastgesteld. De procentuele
variatiecoefficienten voor chloride in het meetbereik tussen 1,2 en 12
mmol/l, nitraat tussen 0,2 en 2 mmol/l, sulfaat tussen 0,1 en 1,2 en bromide
tussen 0,05 en 0,5 mmol/l zijn beter dan 0,9 %. Voor nitriet bedragen deze
waarden bij 10 umol/l en 100 umol/l respectievelijk 3,4 en 0,67 %. De
aantoonbaarheidsgrenzen voor chloride, nitraat, nitriet, sulfiet, sulfaat,
en bromide bedragen 2 umol/l. De toepasbaarheid van de methode is getoetst
in diverse matrices, zoals regenwatermonsters, drinkwatermonsters, een CRM,
grondwatermonsters en extracten van luchtfilters. De resultaten van
ionchromatografische analyses van verschillende systemen in diverse matrices
zijn vergeleken. Voorbehandeling is voor de meeste analyses niet
noodzakelijk. Het onderzoek werd verricht in de periode januari 1999 tot
februari 2000.
Results are described here of performance characteristics of an automated ion chromatographic method for the simultaneous determinations of analytes in water. The microbore gradient method is equipped with an on-line eluent generator and a microbore suppressor in the recycling mode. The repeatability, trueness, recovery, limits of detection and matrix effects were investigated. No pretreatment was necessary for most of the regular matrices. The repeatability for chloride between 1.2 and 12 mmol/l; nitrate between 0.2 and 2 mmo/l, sulfate between 0.1 and 1.2 mmol/l and bromide between 0.05 and 0.5 mmol/l is better than 0.9%. The repeatability for nitrite at 10 4mol/l and 100 4mol/l is 3.40% and 0.67%, respectively. The limits of detection for chloride, nitrate, nitrite, sulfate and bromide amounted to 2 4mol/l. Application of the method was tested for drinking water, rainwater, groundwater, surface water and water extracts from air filters. The results of the analysis have been compared with previous applied methods.
Results are described here of performance characteristics of an automated ion chromatographic method for the simultaneous determinations of analytes in water. The microbore gradient method is equipped with an on-line eluent generator and a microbore suppressor in the recycling mode. The repeatability, trueness, recovery, limits of detection and matrix effects were investigated. No pretreatment was necessary for most of the regular matrices. The repeatability for chloride between 1.2 and 12 mmol/l; nitrate between 0.2 and 2 mmo/l, sulfate between 0.1 and 1.2 mmol/l and bromide between 0.05 and 0.5 mmol/l is better than 0.9%. The repeatability for nitrite at 10 4mol/l and 100 4mol/l is 3.40% and 0.67%, respectively. The limits of detection for chloride, nitrate, nitrite, sulfate and bromide amounted to 2 4mol/l. Application of the method was tested for drinking water, rainwater, groundwater, surface water and water extracts from air filters. The results of the analysis have been compared with previous applied methods.