Determination of histamine and 1-methylhistamine in human plasma by high-performance liquid chromatography and fluorescence detection
Wubs KL ; Stolker AAM ; Kortboyer JM ; Meulenbelt J ; van Ginkel LA
Wubs KL
Stolker AAM
Kortboyer JM
Meulenbelt J
van Ginkel LA
Citations
Altmetric:
Series / Report no.
Open Access
Type
Report
Language
en
Date of publication
1997-11-30
Year of publication
Research Projects
Organizational Units
Journal Issue
Title
Determination of histamine and 1-methylhistamine in human plasma by high-performance liquid chromatography and fluorescence detection
Translated Title
Bepaling van histamine en 1-methylhistamine in humaan plasma met behulp van hoge-druk vloeistofchromatografie en fluorescentie detectie
Published in
Abstract
Voor de bepaling van histamine en 1-methylhistamine (=Nt-methylhistamine=histamine metaboliet) in humaanplasma is de vloeistofchromatografische methode gebruikt. De uit het plasma geextraheerde histaminen werden met behulp van fluorescamine gederivatiseerd tot fluorescerende verbindingen. De derivaten werden met behulp van HPLC gescheiden op een octadecylsilica-kolom met als eluens een mengsel van 25 mM fosfaatbuffer (pH=9.1)/ acetronitril. De derivaten werden met behulp van een fluorescentiedetector gedetecteerd. De binnen laboratorium reproduceerbaarheid varieerde voor histamine tussen 52-7% (n=2) binnen het concentratiegebied van 1.7-24.7 mug/l en dat voor het 1-methylhistamine varieerde van 86-41% (n=2) binnen het concentratiegebied van 1.4-20.4 mug/l. Deze waarden waren voor histamine acceptabel maar te hoog voor het kwantitatief bepalen van 1-methylhistamine.<br>
This report describes a method for the determination of histamine and 1-methylhistamine (=Nt-methylhistamine) in samples of human plasma. The analytes were extracted from the sample using a cation-exchange solid-phase extraction cartridge and derivatized to fluorescense compounds with fluorescamine. The derivatives were detected using a fluorescence detection. The standard curve for histamine was linear within the range of 1.7-24.7 mug/l and for 1-methylhistamine within the range of 1.4-20.4 mug/l. The within-laboratory reproducibility for histamine varied from 52-7% (n=2) for the concentration range of 1.7-24.7 mug/l. The within-laboratory reproducibility for 1-methylhistamine varied from 86-41% (n=2) for the concentration range of 1.4-20.4 mug/l. These values were acceptable for histamine but too high for accurate quantification of 1-methylhistamine.<br>
This report describes a method for the determination of histamine and 1-methylhistamine (=Nt-methylhistamine) in samples of human plasma. The analytes were extracted from the sample using a cation-exchange solid-phase extraction cartridge and derivatized to fluorescense compounds with fluorescamine. The derivatives were detected using a fluorescence detection. The standard curve for histamine was linear within the range of 1.7-24.7 mug/l and for 1-methylhistamine within the range of 1.4-20.4 mug/l. The within-laboratory reproducibility for histamine varied from 52-7% (n=2) for the concentration range of 1.7-24.7 mug/l. The within-laboratory reproducibility for 1-methylhistamine varied from 86-41% (n=2) for the concentration range of 1.4-20.4 mug/l. These values were acceptable for histamine but too high for accurate quantification of 1-methylhistamine.<br>
Description
Publisher
Rijksinstituut voor Volksgezondheid en Milieu RIVM
Sponsors
IGB