Vergelijkend onderzoek van het stellen van natriumthiosulfaat- en kaliumbromaatoplossingen met visuele en automatische eindpuntsbepaling
Esseveld FG van ; Graaf M de ; Cleven RFMJ
Esseveld FG van
Graaf M de
Cleven RFMJ
Citations
Altmetric:
Series / Report no.
Open Access
Type
Report
Language
nl
Date of publication
1990-09-30
Year of publication
Research Projects
Organizational Units
Journal Issue
Title
Vergelijkend onderzoek van het stellen van
natriumthiosulfaat- en kaliumbromaatoplossingen met visuele en automatische
eindpuntsbepaling
Translated Title
Comparison of the standardizations of sodium
thiosulphate- and potassium bromate solutions by visual and automatic
end-point titration.
Published in
Abstract
Abstract niet beschikbaar
The possibility to determine the strength of a sodiumthiosulphate solution (0.1 mol/l) and a potassium bromate-potassium bromide solution (0.017 mol/l) using an automatic titrator has been investigated. The equivalence point of the redox titrations has been visually as well as automatically determined. The redox potential has been measured using a platinum electrode with a silver/ silverchloride reference electrode. The results of the automatic titrations of sodiumthiosulphate solutions do not differ statistically from the results obtained with the manual titration according to the procedure described in NEN 3103. The results of the automatic titrations of potassiumbromate-potassiumbromide solutions do not differ statistically from the results obtained with the manual titration according to the procedure described in the standard operating procedure SOP LAC / 006.
The possibility to determine the strength of a sodiumthiosulphate solution (0.1 mol/l) and a potassium bromate-potassium bromide solution (0.017 mol/l) using an automatic titrator has been investigated. The equivalence point of the redox titrations has been visually as well as automatically determined. The redox potential has been measured using a platinum electrode with a silver/ silverchloride reference electrode. The results of the automatic titrations of sodiumthiosulphate solutions do not differ statistically from the results obtained with the manual titration according to the procedure described in NEN 3103. The results of the automatic titrations of potassiumbromate-potassiumbromide solutions do not differ statistically from the results obtained with the manual titration according to the procedure described in the standard operating procedure SOP LAC / 006.
Description
Publisher
Sponsors
RIVM