dc.description.abstractThis report deals with the operationalization of Spectro P ISP-AES instrument for the analysis of groundwater and drinking water. Choices were made for the settings of the various instrumental parameters. Performance characteristics were established and compared with the specifications supplied. The instrument met the suppliers specifications with respect to detection limits, stability and precision. A comparative investigation with the formerly used equipment showed no significant or relevant differences in the results.
dc.format.extent554774 bytes
dc.format.mimetypeapplication/pdf
dc.language.isonlen_US
dc.publisherRijksinstituut voor Volksgezondheid en Milieu RIVMen_US
dc.relation.ispartofseriesRIVM Rapport 502501002en_US
dc.relation.urlhttp://www.rivm.nl/bibliotheek/rapporten/502501002.htmlen_US
dc.subject.othergroundwateren
dc.subject.otherdrinking wateren
dc.subject.otheranalytical methodsen
dc.subject.othermeasurement equipmenten
dc.subject.otherspectro pen
dc.subject.othericp-easen
dc.subject.otherperformanceen
dc.subject.othercharacteristicsen
dc.subject.otherprestatiekenmerkenen
dc.subject.othergrondwaternl
dc.subject.otherdrinkwaternl
dc.subject.otheranalyse methodennl
dc.subject.othermeetapparatuurnl
dc.titleOperationalisering en prestatiekenmerken van een spectro P ICP-AES opstelling voor de analyse van grond- en drinkwateren_US
dc.title.alternative[Operationalization of a sectro P ICP-AES instrument for the analysis of groundwater and drinking water.]en_US
dc.typeReport
refterms.dateFOA2018-12-18T08:20:17Z
html.description.abstractThis report deals with the operationalization of Spectro P ISP-AES instrument for the analysis of groundwater and drinking water. Choices were made for the settings of the various instrumental parameters. Performance characteristics were established and compared with the specifications supplied. The instrument met the suppliers specifications with respect to detection limits, stability and precision. A comparative investigation with the formerly used equipment showed no significant or relevant differences in the results.


Files in this item

Thumbnail
Name:
502501002.pdf
Size:
541.7Kb
Format:
PDF

This item appears in the following Collection(s)

Show simple item record