dc.description.abstractAbstract niet beschikbaar
dc.description.abstractEmissions of some components in the stack gas of the municipal solid waste incinerator (MSWI) ARN in Weurt are higher than the maximum allowed emissions according to a standard, which will be effective from 30 november 1993. Emissions show an average dioxin concentration in the stack gas of ca. 6 ng TEQ/Nm3 (dry, 11% oxygen). This concentration is considered to be low for this type of installation, when compared with other types of MSWIs in the Netherlands. The yearly emission of dioxins from this installation is estimated at ca. 3 g TEQ. The contribution of the ARN to the maximum deposition is estimated at 15 ng TEQ/(m2. year) at 700 m North-East of the installation. Background depositions are estimated at 5 ng TEQ/(m2.year). From the measured emission a dioxin concentration of ca. 2 pg TEQ/g milk fat is predicted in the deposition maximum with a model system. So there is only a faint chance of exceeding the standard for milk of 6 pg TEQ/g milk fat. Determination of dioxin levels in milk, grass and soil in this area is therefore not recommended.
dc.description.sponsorshipHIMH
dc.format.extent15 p
dc.language.isonl
dc.relation.ispartofRIVM Rapport 730501032
dc.relation.urlhttp://www.rivm.nl/bibliotheek/rapporten/730501032.html
dc.subject17nl
dc.subject91-2nl
dc.subjectvuilverbrandingnl
dc.subjectarnnl
dc.subjectavi-weurtnl
dc.subjectemissiesnl
dc.subjectdioxinennl
dc.subjectpcdd/pcdf; incinerationnl
dc.subjectmswi-weurtnl
dc.subjectemissionsnl
dc.subjectdioxinsnl
dc.subject923nl
dc.titleEvaluatie van de dioxine-emissies van de afvalverbrandingsinstallatie in Weurtnl
dc.title.alternativeEvaluation of the dioxin emissions of the municipal solid waste incinerator in Weurten
dc.typeReport
dc.date.updated2012-12-12T12:07:02Z
html.description.abstractAbstract niet beschikbaar
html.description.abstractEmissions of some components in the stack gas of the municipal solid waste incinerator (MSWI) ARN in Weurt are higher than the maximum allowed emissions according to a standard, which will be effective from 30 november 1993. Emissions show an average dioxin concentration in the stack gas of ca. 6 ng TEQ/Nm3 (dry, 11% oxygen). This concentration is considered to be low for this type of installation, when compared with other types of MSWIs in the Netherlands. The yearly emission of dioxins from this installation is estimated at ca. 3 g TEQ. The contribution of the ARN to the maximum deposition is estimated at 15 ng TEQ/(m2. year) at 700 m North-East of the installation. Background depositions are estimated at 5 ng TEQ/(m2.year). From the measured emission a dioxin concentration of ca. 2 pg TEQ/g milk fat is predicted in the deposition maximum with a model system. So there is only a faint chance of exceeding the standard for milk of 6 pg TEQ/g milk fat. Determination of dioxin levels in milk, grass and soil in this area is therefore not recommended.