• Login
    View Item 
    •   Home
    • RIVM official reports
    • RIVM official reports
    • View Item
    •   Home
    • RIVM official reports
    • RIVM official reports
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Browse

    RIVM Publications RepositoryCommunitiesTitleAuthorsIssue DateSubmit Date

    My Account

    LoginRegister

    Statistics

    Display statistics

    Arseen, cadmium en kwik in urine: monsteropslag en houdbaarheid

    • CSV
    • RefMan
    • EndNote
    • BibTex
    • RefWorks
    Average rating
     
       votes
    Cast your vote
    You can rate an item by clicking the amount of stars they wish to award to this item. When enough users have cast their vote on this item, the average rating will also be shown.
    Star rating
     
    Your vote was cast
    Thank you for your feedback
    Authors
    Loon JW van
    Bom CM
    Heerde E van
    Ooik A van
    Ritsema R
    Type
    Report
    Language
    nl
    
    Metadata
    Show full item record
    Title
    Arseen, cadmium en kwik in urine: monsteropslag en houdbaarheid
    Translated Title
    Arsenic, cadmium and mercury in urine: sample storage and stability
    Publiekssamenvatting
    Vooruitlopend op de studie naar de blootstelling van de bevolking aan milieucontaminanten werd onderzoek verricht naar bewaaromstandigheden van humane urine waarbij de concentraties aan arseen, cadmium en kwik voldoende stabiel dienden te blijven teneinde een ruime tijdmarge te hebben tussen monstername en analyse. Voor dit doel werd door enkele vrijwilligers een monster 'spot'-urine verzameld. De concentraties aan arseen en kwik in urinemonsters werden gemeten met recent ontwikkelde en gevalideerde methoden. De methode voor de bepaling van arseen is gebaseerd op een atoomabsorptiemeting na hydridevorming. De aantoonbaarheidsgrens voor arseen bedroeg 0,45 mug As/l. De concentraties aan arseen in urinemonsters, opgeslagen bij 5 +- 4 graden C in polyethyleen vaatjes, zijn tenminste drie weken stabiel. De concentratie aan cadmium in urine werd gemeten met vlamloze atomaire absorptie met Zeeman achtergrondcorrectie. De aantoonbaarheidsgrens voor deze methode bedroeg 0,03 mug Cd/l. De concentraties aan cadmium in urinemonsters, opgeslagen bij 5 +- 4 graden C in polyethyleen vaatjes, zijn tenminste drie weken stabiel. De stabiliteit van kwik in urine tijdens de monsteropslag is bij verschillende bewaaromstandigheden onderzocht. Voor de meting van de veranderingen van de kwikconcentraties tijdens de opslagperiode werd gebruik gemaakt van de atomaire fluorescentie spectrometrische (AFS-) analysemethode waarmee een aantoonbaarheidsgrens van 0,2 mug Hg/l haalbaar bleek. Urine die in polyethyleen (kunststof) vaten is bemonsterd dient voor de bepaling van kwik binnen 80 uur met broom en zoutzuur te worden voorbehandeld en naar borosilicaat glazen vaten te worden overgebracht die bij 5+- 4 graden C en in het donker worden opgeslagen. Wanneer de urine onder deze omstandigheden wordt opgeslagen blijft de kwikconcentratie gedurende tenminste 37 etmalen stabiel.
    Prior to the study on the exposure of environmental contaminants to the human population, the storage conditions necessary for human urine stability were investigated by testing for sufficient stabilisation of arsenic, cadmium and mercury concentrations, allowing a considerable time margin between sample collection and sample analyses. Spot-urine samples of a number of volunteers were used for this purpose. Methods for the determination of arsenic and mercury in urine samples have already been developed and validated in the recent past. The method for the determination of arsenic is based on atomic absorption spectrometry after hydride generation, where the detection limit for arsenic is 0.45 mug As/l. Urine samples stored at 5 +- 4 degrees C in polyethylene vessels were found stable in arsenic concentrations for over three weeks. Cadmium concentrations in urine samples are measured by flameless atomic absorption spectrometry with Zeeman background correction, with the detection limit of this method being 0.03 mug Cd/l. Urine samples stored at 5 +- 4 degrees C in polyethylene vessels were found stable in cadmium concentrations for over three weeks. The stability of mercury in urine during storage was studied using atomic fluorescence spectrometry (AFS), with a method detection limit of 0.2 mug Hg/l. To maintain stability, urine samples should be stored in borosilicate glass vessels within 80 hours of sampling and kept in the dark at 5 +- 4 degrees C. Before storage the urine samples should be treated with bromine and hydrochloric acid. For urine stored under these conditions, the mercury concentration is stable for at least 37 days.
    Sponsors
    IGZ
    URI
    http://hdl.handle.net/10029/255662
    Collections
    RIVM official reports

    entitlement

     

    DSpace software (copyright © 2002 - 2023)  DuraSpace
    Quick Guide | Contact Us
    Open Repository is a service operated by 
    Atmire NV
     

    Export search results

    The export option will allow you to export the current search results of the entered query to a file. Different formats are available for download. To export the items, click on the button corresponding with the preferred download format.

    By default, clicking on the export buttons will result in a download of the allowed maximum amount of items.

    To select a subset of the search results, click "Selective Export" button and make a selection of the items you want to export. The amount of items that can be exported at once is similarly restricted as the full export.

    After making a selection, click one of the export format buttons. The amount of items that will be exported is indicated in the bubble next to export format.