• Login
    View Item 
    •   Home
    • RIVM official reports
    • RIVM official reports
    • View Item
    •   Home
    • RIVM official reports
    • RIVM official reports
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Browse

    All of WARPCommunitiesTitleAuthorsIssue DateSubmit DateSubjectsPublisherDepartmentThis CollectionTitleAuthorsIssue DateSubmit DateSubjectsPublisherDepartment

    My Account

    LoginRegister

    Statistics

    Display statistics

    Ontwikkeling van een diffusieproef voor PCB, OCB en EOX

    • CSV
    • RefMan
    • EndNote
    • BibTex
    • RefWorks
    Average rating
     
       votes
    Cast your vote
    You can rate an item by clicking the amount of stars they wish to award to this item. When enough users have cast their vote on this item, the average rating will also be shown.
    Star rating
     
    Your vote was cast
    Thank you for your feedback
    Authors
    van der Velde EG
    Broekman MH
    Orbons AJ
    Type
    Onderzoeksrapport
    Language
    nl
    
    Metadata
    Show full item record
    Title
    Ontwikkeling van een diffusieproef voor PCB, OCB en EOX
    Translated Title
    Investigations for a tank leaching test for PCB, OCB and EOX
    Publiekssamenvatting
    In het kader van de uitloogkarakterisering van bouw- en afvalstoffen is onderzoek uitgevoerd ten behoeve van de ontwikkeling van een diffusieproef op PCB, OCB en EOX. Diffusieproeven, gebaseerd op NEN 7345 en gemodificeerd aan de hand van een intern RIVM-voorschrift, zijn uitgevoerd op een viertal verschillende cementstabilisaten bereid op basis van grond, zeefzand, bouwpuin en straalgrit. Het doel van de werkzaamheden was gelegen in het vaststellen van de praktische uitvoerbaarheid van de proef, het niveau van de emissies, de herhaalbaarheid van de proef, en het mechanisme van de uitloging. Daarnaast is onderzoek gedaan naar verliezen van OCB ten gevolge van adsorptie tijdens de uitloogproef. Het gemodificeerde voorschrift voorziet in een goede praktische uitvoerbaarheid van de proef. Verliezen ten gevolge van (reversibele) adsorptie aan de wand van de glazen diffusiebakken zijn relatief gering. Het niveau van de in de eluaten van de diffusieproeven (uitgevoerd op sterk verontreinigde materialen) gemeten concentraties, ligt voldoende hoog boven bepalingsgrensniveau om onderscheidende uitspraken te kunnen doen over bouwmaterialen en afvalstoffen. Er bestaan sterke verschillen tussen het uitlooggedrag van de verschillende individuele PCB en OCB. De gemeten emissie, uitgedrukt als percentage van de samenstellingswaarde varieert voor de verschillende materialen en de verschillende componenten tussen de orde van 1 % en 0.01 %. Hierbij is de relatieve emissie van de lichtere, beter oplosbare componenten hoger dan de emissie van de zwaardere componenten. De waargenomen standaarddeviaties van duplometingen lijken niet hoger dan de in NEN 7345 voor anorganische contaminanten vermelde waarden. Het mechanisme van de uitloging van PCB, OCB en EOX uit de onderzochte materialen is vooralsnog niet geheel duidelijk. Er zijn echter ook aanwijzingen dat er sprake is van een combinatie van mechanismen (afspoeling, oplossing, diffusie, uitputting).Er wordt voorgesteld een ontwerp-NVN voor diffusieproeven op PAK, PCB, OCB en EOX op te stellen met als doel het bieden van een systematiek om via een geuniformeerde aanpak ervaring op te doen en de kennis uit te breiden met betrekking tot de uitloging van deze contaminanten uit vormgegeven materialen.<br>
    Within the framework of the Terms of Reference Plan for normalization commission 39011 on "Leaching characteristics of building and waste materials", the National Institute of Public Health and the Environment (RIVM) is developing a set of leaching tests for various organic compounds. Laboratory investigations for the development of tank leaching tests PCB, organochlorine pesticides (OCB) and extractable organic halogenated compounds (EOX) were performed between 1994-1997 to assess the practical feasibility of the experimental set-up, the level of emissions, the reproducibility of the experiments and the mechanism of the leaching of PAH. Additional experiments were performed to investigate the losses of OCB due to adsorption during the tank leaching test. Tank leaching tests for PCB, OCB and EOX, based on Dutch NEN 7345 and modified according to an internal RIVM method, were performed on four different cement-stabilized contaminated materials. The materials contained high levels of contaminants because it is expected that an important use of the tank leaching test will be the environmental assessment of stabilized wastes, which often have a high degree of contamination. These high levels also ensure detectable leached quantities. With reference to the performance, the modified method shows a good and practical feasibility of the test. Leachates seemed to be homogeneous enough to allow for partial extraction and analysis of (filtered) leachates. Losses of OCB due to (reversible) adsorption to the surface of the tank used for leaching were low. The level of emissions from the (highly contaminated) materials investigated was high enough to discriminate between different building and waste materials. Standard deviations (n=2) were comparable to those reported in Appendix A of NEN 7345. The mechanism of leaching of PCB, OCB and EOX from the materials investigated is not clear; this leaching may be due to a combination of several different mechanisms.<br>
    Publisher
    Rijksinstituut voor Volksgezondheid en Milieu RIVM
    Sponsors
    DGM/DB
    Collections
    RIVM official reports

    entitlement

     

    DSpace software (copyright © 2002 - 2021)  DuraSpace
    Quick Guide | Contact Us
    Open Repository is a service operated by 
    Atmire NV
     

    Export search results

    The export option will allow you to export the current search results of the entered query to a file. Different formats are available for download. To export the items, click on the button corresponding with the preferred download format.

    By default, clicking on the export buttons will result in a download of the allowed maximum amount of items.

    To select a subset of the search results, click "Selective Export" button and make a selection of the items you want to export. The amount of items that can be exported at once is similarly restricted as the full export.

    After making a selection, click one of the export format buttons. The amount of items that will be exported is indicated in the bubble next to export format.