A comparison of automated measurements of air quality near Valthermond (NL) in 2004
Average rating
Cast your vote
You can rate an item by clicking the amount of stars they wish to award to this item.
When enough users have cast their vote on this item, the average rating will also be shown.
Star rating
Your vote was cast
Thank you for your feedback
Thank you for your feedback
Series/Report no.
RIVM rapport 680500003Type
ReportLanguage
en
Metadata
Show full item recordTitle
A comparison of automated measurements of air quality near Valthermond (NL) in 2004Translated Title
Vergelijkende metingen LUEN RIVM in ValthermondPubliekssamenvatting
In 2004 werd een gezamenlijke meetcampagne opgezet tussen het Duitse LUEN en het Nederlandse RIVM om een internationale bevestiging van de meetresultaten te verkrijgen. De campagne werd uitgevoerd op een landelijk meetpunt dichtbij Valthermond. Dit rapport geeft de resultaten van de componenten PM10, NO, NO2, O3 en NH3 over 2004. De verschillen zijn meestal binnen aanvaardbare grenzen en verklaarbaar. Voor O3 zijn de verschillen niet volledig verklaard. Dit is een punt van aandacht. Deze campagne laat op een constructieve wijze zien hoe kwaliteit en internationale vergelijkbaarheid van de door elk instituut geproduceerde gegevens verbeteren. De uitwisseling van ervaringen heeft een lerend effect. Om de oorzaak en de oplossing voor de verschillen verder te onderzoeken zal de campagne in 2005 worden voortgezet.In 2004 a simultaneous measurement programme was set up between the German LUEN and the Dutch RIVM to obtain an international validation of the results. The programme took place at a rural station near Valthermond, in the northeast of the Netherlands. This report states the results from the calendar year 2004 for the components PM10, NO, NO2, O3 and NH3. The differences observed were mostly within acceptable limits and could be explained. However the differences for O3 cannot be fully explained and this requires further attention. The programme led to a constructive improvement in the quality of the data produced by each institute and showed us how to improve the international comparability. Further much was learned from the experiences exchanged. The programme will be continued at the Valthermond site in 2005 to investigate the underlying causes in the differences and to resolve these.
Publisher
Staatliches Gewerbeaufsichtsamt HildesheimZentrale Unterstutzungsstelle LG
Luftreinhaltung Gefahrstoffe
Hannover
Sponsors
VROM-DGMCollections