• Login
    View Item 
    •   Home
    • RIVM official reports
    • RIVM official reports
    • View Item
    •   Home
    • RIVM official reports
    • RIVM official reports
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Browse

    RIVM Publications RepositoryCommunitiesTitleAuthorsIssue DateSubmit Date

    My Account

    LoginRegister

    Statistics

    Display statistics

    Toepassingsmogelijkheden van groot-volume-injectie gaschromatografie met infraroodspectrometrische detectie

    • CSV
    • RefMan
    • EndNote
    • BibTex
    • RefWorks
    Average rating
     
       votes
    Cast your vote
    You can rate an item by clicking the amount of stars they wish to award to this item. When enough users have cast their vote on this item, the average rating will also be shown.
    Star rating
     
    Your vote was cast
    Thank you for your feedback
    Authors
    Visser T
    Vredenbregt MJ
    Hankemeier Th
    Hooischuur E
    Laan R van der
    Type
    Report
    Language
    nl
    
    Metadata
    Show full item record
    Title
    Toepassingsmogelijkheden van groot-volume-injectie gaschromatografie met infraroodspectrometrische detectie
    Translated Title
    Applyability of large volumes injection gaschromatography with infrared spectrometric detection
    Publiekssamenvatting
    Onderzoek is uitgevoerd naar verbetering van de relatieve detectiegrenzen van gaschromatografie met infraroodspectrometrische detectie (GC-IR) door toepassing van zogenaamde large-volume injectie (LVI) technieken. Twee technieken zijn onderzocht, loop-type interfacing en on-column interfacing. Optimalisatie is uitgevoerd met n-alkanen in verschillende oplosmiddelen. Pesticiden, polyaromatische koolwaterstoffen en andere contaminanten zijn gebruikt voor het testen van de bruikbaarheid van het ontwikkelde systeem in de milieu-analyse. Bij 100 ul injecties blijkt de relatieve detecteerbaarheid van de niet vluchtige analieten in vergelijking met 1 ul split/splitless injecties, voor beide typen interfacing vrijwel evenredig toe te nemen met het geinjecteerde volume. Bij injectie van grotere volumes (200-400 ul) wordt de winst in relatieve gevoeligheid gedeeltelijk teniet gedaan door verontreinigingen in het oplosmiddel. De prestaties van de on-column interfacing zijn relatief beter door het geringere verlies aan vluchtige componenten en de inbouw van een detector-schakelsysteem. De praktische mogelijkheden van LVI-GC-IR worden gedemonstreerd aan de hand van de analyse van enkele monsters drink- en oppervlaktewater waaraan veel voorkomende contaminanten zijn toegevoegd op een niveau van 0.1-1 ug/l. De toegevoegde componenten zijn gedetecteerd en geidentificeerd (i) via injectie van extracten verkregen via vloeistof-vloeistof extractie en (ii) door on-line desorptie van elders bemonsterde solid phase extracted (SPE) cartridges. De mogelijkheid van (LVI-)GC-IR om door middel van functionele groepschromatogrammen te screenen op de aanwezigheid van specifieke stofklassen is een waardevolle aanvulling op gaschromatografie met massaspectrometrische en atoomemissie detectie.
    Research has been carried out to enlarge the analyte detectability of gaschromatography with infrared spectrometric detection (GC-IR) by techniques that allow injection of large volumes of liquid samples (100 ul typical). Two techniques have been investigated; loop-type and on-column interfacing. Alkanes dissolved in various solvents have been used for optimisation. Pesticides, polyaromatic hydrocarbons and other micro-contaminants have been used to test the usefulness of the eveloped system in environmental trace analysis. The increase in analyte detectability of high boiling compounds compared to conventional 1 ul split/splitless injection is almost proportional to the injected volume for injection of 100 ul. At larger sample volumes, the increase of the relative sensitivity is partly detracted by impurities of the solvent. The performance of the on-column interface is better due to the reduced loss of volatiles and the incorporation of a detector switching module that minimizes interfering solvent condensation in the IR detection interface. The potentials of LVI-GC-IR are demonstrated by the analysis of samples of drinking and surface water spiked at levels of 0.1-1 ug/l with components that commonly occur as micro-contaminants. Analytes have been detected and identified (i) by direct injection of solutions obtained by liquid-liquid extraction and (ii) by on-line desorption of at site sampled solid phase extracted cartridges. The possibility of (LVI-)GC-IR of selective screening on the prescence of specific compound classes by means of functional group chromatograms makes the technique a valuable tool in addition to GC with mass spectrometric and atomic emission detection.
    Sponsors
    RIVM
    URI
    http://hdl.handle.net/10029/257145
    Collections
    RIVM official reports

    entitlement

     

    DSpace software (copyright © 2002 - 2023)  DuraSpace
    Quick Guide | Contact Us
    Open Repository is a service operated by 
    Atmire NV
     

    Export search results

    The export option will allow you to export the current search results of the entered query to a file. Different formats are available for download. To export the items, click on the button corresponding with the preferred download format.

    By default, clicking on the export buttons will result in a download of the allowed maximum amount of items.

    To select a subset of the search results, click "Selective Export" button and make a selection of the items you want to export. The amount of items that can be exported at once is similarly restricted as the full export.

    After making a selection, click one of the export format buttons. The amount of items that will be exported is indicated in the bubble next to export format.