Show simple item record

dc.contributor.authorMatthijsen AJCM
dc.contributor.authorJaarsveld JA van
dc.contributor.authorJong APJM de
dc.contributor.authorRos JPM
dc.contributor.authorSchutter MAA
dc.contributor.authorVos JJ
dc.date.accessioned2012-12-12T15:23:20Z
dc.date.available2012-12-12T15:23:20Z
dc.date.issued1990-09-30
dc.identifier730501016
dc.identifier.urihttp://hdl.handle.net/10029/257264
dc.description.abstractAbstract niet beschikbaar
dc.description.abstractThe emission measurements at the municipal solid waste incinerator (MSW) AVI-the Hague show an average concentration of 8,3 ng TEQ/Nm3 (dry, 11% oxygen). The measured emission of chlorinated dioxins and furans from this installation has to be considered low for this type of installation in comparison with others in the Netherlands. The yearly emission of these compounds is estimated to be 15 g TEQ/year from this installation. According to dispersion model calculations this emission contributes slightly to the yearly mean deposition in the direct surroundings, viz. on average 2 (1-3) ng TEQ/(m2.year) on an area of 20x20 km2 and a maximum of 6 (5-8) ng TEQ/(m2.year) at 700 m North-East of the installation. The background deposition is estimated at a level of 10 ng TEQ/(m2.year). After closure of the MSW in Leiden this will be 5 ng TEQ/(m2/year). There are no cows grazing in the vicinity of the deposition maximum. Therefore there is no reason for determination of dioxin levels in grass and soil in this area.
dc.description.sponsorshipHIMH
dc.format.extent19 p
dc.language.isonl
dc.relation.ispartofRIVM Rapport 730501016
dc.relation.urlhttp://www.rivm.nl/bibliotheek/rapporten/730501016.html
dc.subject17nl
dc.subjectdioxine-emissiesnl
dc.subjectafvalverbrandingsinstallatienl
dc.subjectavi-den haagnl
dc.titleEvaluatie van de dioxine-emissies van de afvalverbrandingsinstallatie AVI Den Haagnl
dc.title.alternativeEvaluation of the dioxin-emissions of the waste incineration plant in the Hagueen
dc.typeOnderzoeksrapport
dc.date.updated2012-12-12T15:23:21Z
html.description.abstractAbstract niet beschikbaar
html.description.abstractThe emission measurements at the municipal solid waste incinerator (MSW) AVI-the Hague show an average concentration of 8,3 ng TEQ/Nm3 (dry, 11% oxygen). The measured emission of chlorinated dioxins and furans from this installation has to be considered low for this type of installation in comparison with others in the Netherlands. The yearly emission of these compounds is estimated to be 15 g TEQ/year from this installation. According to dispersion model calculations this emission contributes slightly to the yearly mean deposition in the direct surroundings, viz. on average 2 (1-3) ng TEQ/(m2.year) on an area of 20x20 km2 and a maximum of 6 (5-8) ng TEQ/(m2.year) at 700 m North-East of the installation. The background deposition is estimated at a level of 10 ng TEQ/(m2.year). After closure of the MSW in Leiden this will be 5 ng TEQ/(m2/year). There are no cows grazing in the vicinity of the deposition maximum. Therefore there is no reason for determination of dioxin levels in grass and soil in this area.


This item appears in the following Collection(s)

Show simple item record