    Standaardisatie van persoonsdosimetrie bij beroepsmatige blootstelling aan ioniserende straling

    • CSV
    • RefMan
    • EndNote
    • BibTex
    • RefWorks
    Thumbnail
    Name:
    861007001.pdf
    Size:
    278.1Kb
    Format:
    PDF
    Download
    Average rating
     
       votes
    Cast your vote
    You can rate an item by clicking the amount of stars they wish to award to this item. When enough users have cast their vote on this item, the average rating will also be shown.
    Star rating
     
    Your vote was cast
    Thank you for your feedback
    Authors
    Eleveld H
    Tanzi CP
    Type
    Report
    Language
    nl
    
    Metadata
    Show full item record
    Title
    Standaardisatie van persoonsdosimetrie bij beroepsmatige blootstelling aan ioniserende straling
    Translated Title
    Standardisation of individual monitoring for occupational exposures to ionising radiation
    Publiekssamenvatting
    In opdracht van het Ministerie van Sociale Zaken en Werkgelegenheid is een onderzoek gedaan naar de standaardisatie van persoonsdosimetrie bij beroepsmatige blootstelling aan ioniserende straling. Wettelijk is voorgeschreven dat de effectieve of equivalente doses van blootgestelde werkers moeten worden bepaald. Overeenkomstig de doelstelling van het onderzoek is een overzicht gegeven van mogelijkheden om het meetresultaat van de persoonsdosismeter te vertalen naar een effectieve dosis en vast te leggen in het Nationaal Dosisregistratie en Informatiesysteem (NDRIS). Daarmee is de mogelijkheid gecreeerd de in NDRIS geregistreerde dosis een zo juist mogelijke weergave te laten zijn van de werkelijk ontvangen (effectieve) dosis. Op basis van beschikbare literatuur en door het voorleggen van vragen aan experts op het gebied van stralingsbescherming en werkprotocollen is een viertal beleidsopties voor het eventueel toepassen van een correctiefactor voorgesteld. Een dergelijke correctie zou alleen van toepassing zijn in de medische praktijk en slechts in die gevallen dat een dosismeter op kraaghoogte buiten het loodschort wordt gedragen. Wij bevelen aan om overeenkomstig met de rest van Europa geen correctie op de gemeten dosis toe te passen. Voorts wordt door ons het volgende aanbevolen. Slechts indien de maanddosis of vierwekelijkse dosis een afgeleide grenswaarde van een tiende van de jaardosislimiet overschrijdt zou een herbepaling van de effectieve dosis zijn toegestaan. Dit gebeurt in zeven landen binnen de Europese Unie. Deze herbepaling mag worden uitgevoerd door een daartoe bevoegd lokaal deskundige met een stralingshygiene-diploma (minimaal) niveau 3 werkend onder de verantwoordelijkheid van een niveau 2-stralingsdeskundige. Als de gecorrigeerde waarde duidelijk afwijkt van het gemeten persoonsdosisequivalent dan mag de werkgever een verzoek indienen voor een aanpassing van de dosis in het dosisregistratiesysteem bij de Arbeidsinspectie. Als deze het verzoek honoreert dan dient de gecorrigeerde dosis te worden ingevoerd in NDRIS.
    The Ministry of Social Affairs and Employment requested RIVM to investigate the standardisation of individual monitoring for occupational exposures to ionising radiation. Law lays down the assessment of the effective or equivalent dose of exposed workers. According to the objective of this study a summary is provided of possibilities to relate the monitoring results to the effective dose and its registration in the National Dose Registration and Information System (NDRIS). Thus the possibility is created for the data registered in NDRIS to be an accurate feasible representation of the actually received (effective) dose. By using the available literature and consulting experts in the field of radiation protection and work protocols, four policy options for applying correction factors are proposed. Such a correction would only be appropriate for the medical practice and only if the dosimeter is worn outside the lead apron. We recommend, in accordance with all other European countries, not to use a correction on the monitored dose. Furthermore, we recommend the following. Only if the monthly or four weekly dose exceeds a derived limit of one tenth of the annual dose limit, one is allowed to reassess the effective dose. This is done in 7 countries of the European Union. An appropriate local radiation expert (minimum level 3) may carry out this reassessment. The radiation expert must work under the responsibility of a radiation expert with a level 2 qualification. When the corrected value significantly differs from the monitored dose the employer may request the Labour Inspectorate to adjust the dose in the dose registration system. When the Inspectorate honours the request, the corrected dose should be entered into NDRIS.
    Description
    Ook te vinden bij http://docs.szw.nl/pdf/92/2004/92_2004_1_7459.pdf
    Sponsors
    SZW/AG
    URI
    http://hdl.handle.net/10029/257802
    Collections
    RIVM official reports

    entitlement

     

    DSpace software (copyright © 2002 - 2023)  DuraSpace
    Quick Guide | Contact Us
    Open Repository is a service operated by 
    Atmire NV
     

    Export search results

    The export option will allow you to export the current search results of the entered query to a file. Different formats are available for download. To export the items, click on the button corresponding with the preferred download format.

    By default, clicking on the export buttons will result in a download of the allowed maximum amount of items.

    To select a subset of the search results, click "Selective Export" button and make a selection of the items you want to export. The amount of items that can be exported at once is similarly restricted as the full export.

    After making a selection, click one of the export format buttons. The amount of items that will be exported is indicated in the bubble next to export format.