    Praktijkvergelijking van twee typen CO-monitoren

    • CSV
    • RefMan
    • EndNote
    • BibTex
    • RefWorks
    Average rating
     
       votes
    Cast your vote
    You can rate an item by clicking the amount of stars they wish to award to this item. When enough users have cast their vote on this item, the average rating will also be shown.
    Star rating
     
    Your vote was cast
    Thank you for your feedback
    Authors
    Schippers JT
    Buijsman E
    Type
    Report
    Language
    nl
    
    Metadata
    Show full item record
    Title
    Praktijkvergelijking van twee typen CO-monitoren
    Translated Title
    Comparison of two types of CO monitors under field conditions
    Publiekssamenvatting
    Abstract niet beschikbaar
    Comparative measurements with two types of CO monitors (Philips PW 9775 and TECO model 48) have been carried out on different locations mainly in the city environment. Measurement were carried out on 7 days resulting in 40 hourly average values. The main findings are: - the relation between the measurement results of the two monitors can be described by a quadratic function with the Philips monitor always showing the lower values in the concentration range investigated (0-9 mg CO/m3) ; - the Philips monitor shows a threshold value of 0.10-0.15 mg/m3 ; - the differences observed are concentration dependent, increase from 0 to higher concentrations and reach a maximum of 0.70 mg/m3 at 7.0 mg/m3 (TECO value). Above 7.0 mg/m3 the differences decrease again. The origin of the deviations of the Philips monitor is not known. However the regression equation may be explained by assuming suggests a concentration dependent conversion of CO into I2 in the converter unit of the Philips monitor.
    Sponsors
    RIVM
    URI
    http://hdl.handle.net/10029/258074
    Collections
    RIVM official reports

    entitlement

     

    DSpace software (copyright © 2002 - 2023)  DuraSpace
    Quick Guide | Contact Us
    Open Repository is a service operated by 
    Atmire NV
     

    Export search results

    The export option will allow you to export the current search results of the entered query to a file. Different formats are available for download. To export the items, click on the button corresponding with the preferred download format.

    By default, clicking on the export buttons will result in a download of the allowed maximum amount of items.

    To select a subset of the search results, click "Selective Export" button and make a selection of the items you want to export. The amount of items that can be exported at once is similarly restricted as the full export.

    After making a selection, click one of the export format buttons. The amount of items that will be exported is indicated in the bubble next to export format.