Evaluatie van de dioxine-emissies van de afvalverbrandingsinstallatie in Dordrecht
dc.contributor.author | Matthijsen AJCM | |
dc.contributor.author | Jaarsveld JA van | |
dc.contributor.author | Sein AA | |
dc.date.accessioned | 2012-12-12T17:21:03Z | |
dc.date.available | 2012-12-12T17:21:03Z | |
dc.date.issued | 1991-04-30 | |
dc.identifier | 730501029 | |
dc.identifier.uri | http://hdl.handle.net/10029/258622 | |
dc.description.abstract | Abstract niet beschikbaar | |
dc.description.abstract | Emission measurements at the municipal solid waste incinerator (MSWI) GEVUDO in Dordrecht show an average dioxin concentration in the stack gas of ca. 13 ng TEQ/Nm3 (dry, 11% oxygen). This concentration is considered to be low for this type of installation, when compared with other types of MSWIs in the Netherlands. The yearly emission of dioxins from this installation is estimated at 11 g TEQ. The contribution of the GEVUDO to the maximum deposition is estimated at 25 ng TEQ/(m2. year) at 700 m North-East of the installation. Background depositions are estimated at 15 ng TEQ/(m2.year). Direct danger for public health is not expected and determination of dioxin levels in milk, grass or soil in this area is not recommended. | |
dc.description.sponsorship | HIMH | |
dc.format.extent | 15 p | |
dc.language.iso | nl | |
dc.relation.ispartof | RIVM Rapport 730501029 | |
dc.relation.url | http://www.rivm.nl/bibliotheek/rapporten/730501029.html | |
dc.subject | 17 | nl |
dc.subject | 91-2 | nl |
dc.subject | vuilverbranding | nl |
dc.subject | gevudo | nl |
dc.subject | avi-dordrecht | nl |
dc.subject | emissies | nl |
dc.subject | dioxinen; pcdd/pcdf | nl |
dc.subject | incineration | nl |
dc.subject | mswi-dordrecht | nl |
dc.subject | emissions | nl |
dc.subject | dioxins | nl |
dc.title | Evaluatie van de dioxine-emissies van de afvalverbrandingsinstallatie in Dordrecht | nl |
dc.title.alternative | Evaluation of the dioxin emissions of the municipal solid waste incinerator in Dordrecht | en |
dc.type | Report | |
dc.date.updated | 2012-12-12T17:21:03Z | |
html.description.abstract | Abstract niet beschikbaar | |
html.description.abstract | Emission measurements at the municipal solid waste incinerator (MSWI) GEVUDO in Dordrecht show an average dioxin concentration in the stack gas of ca. 13 ng TEQ/Nm3 (dry, 11% oxygen). This concentration is considered to be low for this type of installation, when compared with other types of MSWIs in the Netherlands. The yearly emission of dioxins from this installation is estimated at 11 g TEQ. The contribution of the GEVUDO to the maximum deposition is estimated at 25 ng TEQ/(m2. year) at 700 m North-East of the installation. Background depositions are estimated at 15 ng TEQ/(m2.year). Direct danger for public health is not expected and determination of dioxin levels in milk, grass or soil in this area is not recommended. |