dc.description.abstractAt the end of 1991 the interface part of the VG Plasma Quad 2 plus ICP-MS was modified. This report describes the performance and the level of molecular interferences of the modified ICP-MS apparatus. The apparatus was optimized for maximal sensitivity, maximal stability and minimal contribution of molucular interferences. Detection limits were four to ten times better than with the standard ICP-MS apparatus and ranged from 6 ng/l for Cd to 1,3 mug/l for B. Using indium as an internal standard, the short term stability was <2% RSD and the long term stability was <4% RSD for elements in the mass range m/z = 51-208. Li, Be, B, Bi and Th had higher RSD values due to unsuitability of the internal standard and to memory effects. The precision ranged from 33% RSD at the detection limit to 0.2-0.7% RSD at 1000x higher concentrations (m/z=51-208). Calibration curves were linear up to at least 200 mug/l. Spectral interferences due to compounds of Na, Cl, S, Ca or Mg prevented the analysis of V, Cr, Ni, Cu, Zn, As and Se at low concentration levels (<20 mug/l.)
dc.description.sponsorshipRIVM
dc.format.extent36 p
dc.language.isonl
dc.relation.ispartofRIVM Rapport 211601005
dc.relation.urlhttp://www.rivm.nl/bibliotheek/rapporten/211601005.html
dc.subject18nl
dc.subjectmetalennl
dc.subjectanalysemethodennl
dc.subjectmassaspectrometrienl
dc.subjectmeetapparatuurnl
dc.subjectevaluatienl
dc.subject92-4nl
dc.subjecticp-msnl
dc.subjectmetalsen
dc.subjectanalytical methodsen
dc.subjectmass spectrometryen
dc.subjectmeaurement equipmenten
dc.subjectevaluationen
dc.titleAnalytisch-chemische evaluering van de VG Plasma Quad 2 plus ICP-MS, gemodificeerd met een &quot;high performance&quot; interfacenl
dc.title.alternativeAnalytical chemical evaluation of the VG Plasma Quad 2 plus ICP-MS, modified with a high performance interfaceen
dc.typeReport
dc.date.updated2012-12-12T21:18:53Z
html.description.abstractAbstract niet beschikbaar
html.description.abstractAt the end of 1991 the interface part of the VG Plasma Quad 2 plus ICP-MS was modified. This report describes the performance and the level of molecular interferences of the modified ICP-MS apparatus. The apparatus was optimized for maximal sensitivity, maximal stability and minimal contribution of molucular interferences. Detection limits were four to ten times better than with the standard ICP-MS apparatus and ranged from 6 ng/l for Cd to 1,3 mug/l for B. Using indium as an internal standard, the short term stability was &lt;2% RSD and the long term stability was &lt;4% RSD for elements in the mass range m/z = 51-208. Li, Be, B, Bi and Th had higher RSD values due to unsuitability of the internal standard and to memory effects. The precision ranged from 33% RSD at the detection limit to 0.2-0.7% RSD at 1000x higher concentrations (m/z=51-208). Calibration curves were linear up to at least 200 mug/l. Spectral interferences due to compounds of Na, Cl, S, Ca or Mg prevented the analysis of V, Cr, Ni, Cu, Zn, As and Se at low concentration levels (&lt;20 mug/l.)


This item appears in the following Collection(s)

Show simple item record