• Login
    View Item 
    •   Home
    • RIVM official reports
    • RIVM official reports
    • View Item
    •   Home
    • RIVM official reports
    • RIVM official reports
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Browse

    RIVM Publications RepositoryCommunitiesTitleAuthorsIssue DateSubmit Date

    My Account

    LoginRegister

    Statistics

    Display statistics

    PM10: Validatie en equivalentie 2006

    • CSV
    • RefMan
    • EndNote
    • BibTex
    • RefWorks
    Thumbnail
    Name:
    680708001.pdf
    Size:
    519.2Kb
    Format:
    PDF
    Download
    Average rating
     
       votes
    Cast your vote
    You can rate an item by clicking the amount of stars they wish to award to this item. When enough users have cast their vote on this item, the average rating will also be shown.
    Star rating
     
    Your vote was cast
    Thank you for your feedback
    Authors
    Beijk R
    Hoogerbrugge R
    Hafkenscheid TL
    van Arkel FT
    Stefess GC
    van der Meulen A
    Wesseling JP
    Sauter FJ
    Albers RAW
    Series/Report no.
    RIVM rapport 680708001
    Type
    Report
    Language
    nl
    
    Metadata
    Show full item record
    Title
    PM10: Validatie en equivalentie 2006
    Translated Title
    PM10: Validation and equivalence 2006
    Publiekssamenvatting
    In het Landelijk Meetnet Luchtkwaliteit (LML) wordt op diverse locaties in Nederland fijnstof (PM10) concentraties gemeten. Om de kwaliteit van deze metingen te waarborgen zijn in 2006 een tweetal grote activiteiten ondernomen.
    Als eerste zijn de procedures, meetconfiguraties en instellingen in het meetnet grondig doorgelicht. De bevindingen van de doorlichting van het meetnet hebben geleid tot een hervalidatie. Het effect van deze hervalidatie op de metingen is gering, maar heeft wel geleid tot een vermindering van de meetonzekerheid.
    De tweede activiteit is het uitgevoerde equivalentieonderzoek. In dit onderzoek is de gelijkwaardigheid tussen de automatische PM10-metingen in het LML en de door de EU voorgeschreven referentiemethode aangetoond. Aan de hand van dit onderzoek is voor de PM10-metingen een nieuwe en nauwkeurigere kalibratie bepaald zodat niet langer de interim kalibratiefactor van de EU toegepast hoeft te worden. Het aantonen van de equivalentie tussen de automatische meetmethode en de referentiemeetmethode is volledig gebaseerd op de aanbevelingen die de Clean Air For Europe (CAFE) steering group begin 2006 heeft vastgesteld zodat Nederland geheel conform de Europese voorschriften werkt.
    In het equivalentieonderzoek zijn kalibratiefuncties voor verschillende apparaattypen voor regionale en stedelijke locaties bepaald. De consequentie voor de jaargemiddelden van regionale stations na 2003, die gebruikt zijn voor de Generieke Concentraties voor Nederland (GCN-kaarten) in 2006, is een daling van minder dan 1 mug/m3.
    Met de hervalidatie van meetdata en de resultaten van het equivalentieonderzoek zijn onzekerheden in de PM10-metingen verkleind en voldoen de metingen aan de gestelde kwaliteitseisen.

    In the Dutch National Air Monitoring Network (LML) particulate matter (PM10) is measured at various locations across the Netherlands. In order to ensure the quality of these PM10-measurements two major activities have been carried out.
    First, in the course of 2006 procedures, device configurations and settings in the Monitoring Network have been checked thoroughly. The observations have led to a revalidation of measurement results. The effect of this revalidation on earlier reported measurement values is minor. However, the measurement uncertainty is reduced due to the revalidation.
    Secondly, an equivalence study has been carried out to determine the equivalence between automatic PM10-measurements and the EU reference method. Based on this study the automatic PM10-measurements in the Dutch National Air Monitoring Network have been calibrated. Hence, making use of the interim EU calibration factor is no longer needed. The demonstration of equivalence between the automatic and reference method is performed conform the recommendations of the Clean Air For Europe (CAFE) steering group.
    New calibrations have been determined for both regional and urban situated sites. The consequence of this new calibration on the measurements on regional location after 2003, used for the making of the 2006 Generic Concentrations for the Netherlands (GCN-cards), is less than 1 mug/m3.
    With both the revalidation of historic measurements and the results of the equivalence study, uncertainties in PM10 measurements have declined and comply with required quality requirements.
    Publisher
    Rijksinstituut voor Volksgezondheid en Milieu RIVM
    Sponsors
    DGM
    Collections
    RIVM official reports

    entitlement

     

    DSpace software (copyright © 2002 - 2023)  DuraSpace
    Quick Guide | Contact Us
    Open Repository is a service operated by 
    Atmire NV
     

    Export search results

    The export option will allow you to export the current search results of the entered query to a file. Different formats are available for download. To export the items, click on the button corresponding with the preferred download format.

    By default, clicking on the export buttons will result in a download of the allowed maximum amount of items.

    To select a subset of the search results, click "Selective Export" button and make a selection of the items you want to export. The amount of items that can be exported at once is similarly restricted as the full export.

    After making a selection, click one of the export format buttons. The amount of items that will be exported is indicated in the bubble next to export format.