Flowinjectie-analyse (FIA) voor de bepaling van hydronium in regenwater: applicatie en vergelijkbaarheid
Average rating
Cast your vote
You can rate an item by clicking the amount of stars they wish to award to this item.
When enough users have cast their vote on this item, the average rating will also be shown.
Star rating
Your vote was cast
Thank you for your feedback
Thank you for your feedback
Type
ReportLanguage
nl
Metadata
Show full item recordTitle
Flowinjectie-analyse (FIA) voor de bepaling van hydronium in regenwater: applicatie en vergelijkbaarheidTranslated Title
Flow injection method for the determination of hydronium in rainwater; application and comparisonPubliekssamenvatting
Abstract niet beschikbaarA flow injection method (FIA) for the determination of hydronium in rainwater has been developed and optimized. The lower limit of detection is 2.7 mumol/L-3O+ and the upper limit of detection is 180 mumol/L H-3O+. The standard deviation in the working range is less then 1.5 mumol/L H-3O+. Comparison with the titrimetric method showed a small difference of -2.1 mumol/L H-3O+. Comparison with the hydronium concentration calculated from the pH showed a significant difference of 3.6 mumol/L H-3O+.
Sponsors
RIVMCollections