Variability and cost implications of three generations of the Roche LightCycler® 480.Published in
PloS One 2018; 13(1):e190847Publiekssamenvatting
Real time PCR has become a dominant method for the highly sensitive detection of pathogens in clinical material. Real time PCR can generate a fluorescence signal by using fluorescence labelled probes, allowing us to detect and semi quantify the amount of amplified DNA. Here we test the variability of the detection system and cost implications of three different versions of the LightCycler® 480 (LC480), focusing on the intensity of fluorescence and Cq in monoplex and multiplex rtPCRs. For gastro-intestinal pathogens there was no correlation between the intensity of fluorescence and the Cq value in the different LC480 types. For probes with the dyes FAMTM, HEXTM, Cy5 and Red610 a higher fluorescence intensity was seen in LC480 type II and III compared to LC480 type I. After lowering the probe concentration for the Cy5 dye three-fold (from 0.3μM to 0.1μM) the Cq value remains the same and the intensity of fluorescence decreases. For the LC480 type II and III the difference in fluorescence intensity was much more extreme. The concentration of the different labelled probes can be lowered at least six-fold in LC480 type II and III cyclers while maintaining a fluorescence intensity as high as achieved in the LC480 type I with undiluted probe. In conclusion, the strength of the fluorescence signal of the LightCycler® 480 type III is superior to that of LightCycler® 480 types I and II, allowing the use of lower probe concentrations for all dyes, particularly for the dyes Red610 and Cy5. This results in a two thirds reduction in PCR probe costs. Switching to these newer machines for real-time PCR can reduce dye labelled probe consumption and thus reduce costs significantly.PMID
29329324ae974a485f413a2113503eed53cd6c53
10.1371/journal.pone.0190847
Scopus Count
Collections
Related articles
- Telomere length measurement on the Roche LightCycler 480 Platform.
- Authors: Jodczyk S, Pearson JF, Aitchison A, Miller AL, Hampton MB, Kennedy MA
- Issue date: 2015 Feb
- Two-dye and one- or two-quencher DNA probes for real-time PCR assay: synthesis and comparison with a TaqMan™ probe.
- Authors: Ryazantsev DY, Tsybulsky DA, Prokhorenko IA, Kvach MV, Martynenko YV, Philipchenko PM, Shmanai VV, Korshun VA, Zavriev SK
- Issue date: 2012 Jul
- Interaction of fluorescent dyes with DNA and spermine using fluorescence spectroscopy.
- Authors: Gracie K, Smith WE, Yip P, Sutter JU, Birch DJ, Graham D, Faulds K
- Issue date: 2014 Aug 7
- Ultra-rapid detection of Chlamydia trachomatis by real-time PCR in the LightCycler using SYBR green technology or 5'-nuclease probes.
- Authors: Eickhoff M, Laue T, Ruckes T, Cramer SO, Krupp G, Tiemann C
- Issue date: 2003
- [Use of the real-time RT-PCR method for investigation of small stable RNA expression level in human epidermoid carcinoma cells A431].
- Authors: Nikitina TV, Nazarova NIu, Tishchenko LI, Tuohimaa P, Sedova VM
- Issue date: 2003