Preparation of irritant polymer samples for an in vitro round robin study.
Name:
Publisher version
View Source
Access full-text PDFOpen Access
View Source
Check access options
Check access options
Average rating
Cast your vote
You can rate an item by clicking the amount of stars they wish to award to this item.
When enough users have cast their vote on this item, the average rating will also be shown.
Star rating
Your vote was cast
Thank you for your feedback
Thank you for your feedback
Authors
Coleman, Kelly PGrailer, Thomas P
McNamara, Lori R
Rollins, Beau L
Christiano, Nicholas J
Kandárová, Helena
De Jong, Wim H
Type
ArticleLanguage
en
Metadata
Show full item recordTitle
Preparation of irritant polymer samples for an in vitro round robin study.Published in
Toxicol in Vitro 2018; advance online publication (ahead of print)Publiekssamenvatting
A round robin study using reconstructed human epidermis (RhE) tissues was conducted to test medical device polymer extracts for skin irritation potential. Test samples were four irritant and three non-irritant medical device polymers. Five of these polymer samples were developed and two were obtained commercially. The three non-irritant samples were comprised of 100% 80A polyurethane, one-part silicone, and polyvinyl chloride (PVC). The polyurethane samples were made using a hot-melt process, while the silicone samples were created by mixing and casting. The PVC samples were commercially produced sheets. The four irritant samples were comprised of one-part silicone and 25% heptanoic acid (HA), two-part silicone and 15% sodium dodecyl sulfate (SDS), PVC and 4% Genapol® X-100, and PVC and 5.8% Genapol® X-080. The HA, SDS, and Genapol® X-100 samples were produced using the mixing and casting method, while the Genapol® X-080 sheet samples were obtained commercially. During development, irritant polymer samples were extracted using polar and non-polar solvents that were subsequently analyzed chemically. Samples with sufficient levels of extracted irritants were tested on RhE tissues to confirm their irritation potential. Polymers that passed this screening test were used in the round robin study described elsewhere in this special edition.PMID
29409881ae974a485f413a2113503eed53cd6c53
10.1016/j.tiv.2018.01.018
Scopus Count
Collections
Related articles
- SkinEthic™ RHE for in vitro evaluation of skin irritation of medical device extracts.
- Authors: Pellevoisin C, Videau C, Briotet D, Grégoire C, Tornier C, Alonso A, Rigaudeau AS, Bouez C, Seyler N
- Issue date: 2018 Aug
- Round robin study to evaluate the reconstructed human epidermis (RhE) model as an in vitro skin irritation test for detection of irritant activity in medical device extracts.
- Authors: De Jong WH, Hoffmann S, Lee M, Kandárová H, Pellevoisin C, Haishima Y, Rollins B, Zdawczyk A, Willoughby J, Bachelor M, Schatz T, Skoog S, Parker S, Sawyer A, Pescio P, Fant K, Kim KM, Kwon JS, Gehrke H, Hofman-Hüther H, Meloni M, Julius C, Briotet D, Letasiova S, Kato R, Miyajima A, De La Fonteyne LJJ, Videau C, Tornier C, Turley AP, Christiano N, Rollins TS, Coleman KP
- Issue date: 2018 Aug
- The suitability of reconstructed human epidermis models for medical device irritation assessment: A comparison of In Vitro and In Vivo testing results.
- Authors: De Jong WH, Carraway JW, Liu C, Fan C, Liu J, Turley AP, Rollins TS, Coleman KP
- Issue date: 2020 Dec
- Evaluation of the medical devices benchmark materials in the controlled human patch testing and in the RhE in vitro skin irritation protocol.
- Authors: Kandárová H, Bendova H, Letasiova S, Coleman KP, De Jong WH, Jírova D
- Issue date: 2018 Aug
- Pre-validation of an in vitro skin irritation test for medical devices using the reconstructed human tissue model EpiDerm™.
- Authors: Kandarova H, Willoughby JA, De Jong WH, Letasiova S, Milasova T, Bachelor MA, Breyfogle B, Handa Y, De la Fonteyne L, Coleman KP
- Issue date: 2018 Aug