    Evaluation of the medical devices benchmark materials in the controlled human patch testing and in the RhE in vitro skin irritation protocol.

    • CSV
    • RefMan
    • EndNote
    • BibTex
    • RefWorks
    Thumbnail
    Name:
    Publisher version
    View Source
    Access full-text PDFOpen Access
    View Source
    Check access options
    Check access options
    Average rating
     
       votes
    Cast your vote
    You can rate an item by clicking the amount of stars they wish to award to this item. When enough users have cast their vote on this item, the average rating will also be shown.
    Star rating
     
    Your vote was cast
    Thank you for your feedback
    Authors
    Kandárová, Helena
    Bendova, Hana
    Letasiova, Silvia
    Coleman, Kelly P
    De Jong, Wim H
    Jírova, Dagmar
    Type
    Article
    Language
    en
    
    Metadata
    Show full item record
    Title
    Evaluation of the medical devices benchmark materials in the controlled human patch testing and in the RhE in vitro skin irritation protocol.
    Published in
    Toxicol in Vitro 2018; advance online publication (ahead of print)
    Publiekssamenvatting
    Several irritants were used in the in vitro irritation medical device round robin. The objective of this study was to verify their irritation potential using the human patch test (HPT), an in vitro assay, and in vivo data. The irritants were lactic acid (LA), heptanoic acid (HA), sodium dodecyl sulfate (SDS), Genapol® X-80 (GP), and Y-4 polymer. Dilute saline and sesame seed oil (SSO) solutions of each were evaluated using a 4 and 18 h HPT and the EpiDerm™ SIT-MD RhE assay; results were then compared to existing rabbit skin irritation test data. Results from the 4 h HPT were negative in most cases except for GP and SDS, while the 18 h HPT also identified some LA, HA, and GP samples as irritants. EpiDerm™ SIT-MD correctly identified all irritants except GP in SSO due to limited solubility. Data from cutaneous rabbit irritation tests were negative, while all intracutaneous results were strongly or weakly positive except for the most dilute GP solutions. These findings indicate that EpiDerm™ SIT-MD results correlate with those from the rabbit intracutaneous test and confirm that RhE assays are suitable replacements for animals in evaluating the tissue irritation potential of medical devices.
    DOI
    10.1016/j.tiv.2018.02.009
    PMID
    29462660
    URI
    http://hdl.handle.net/10029/621461
    ae974a485f413a2113503eed53cd6c53
    10.1016/j.tiv.2018.02.009
    Scopus Count
    Collections
    Miscellaneous

    entitlement

    Related articles

    • SkinEthic™ RHE for in vitro evaluation of skin irritation of medical device extracts.
    • Authors: Pellevoisin C, Videau C, Briotet D, Grégoire C, Tornier C, Alonso A, Rigaudeau AS, Bouez C, Seyler N
    • Issue date: 2018 Aug
    • Pre-validation of an in vitro skin irritation test for medical devices using the reconstructed human tissue model EpiDerm™.
    • Authors: Kandarova H, Willoughby JA, De Jong WH, Letasiova S, Milasova T, Bachelor MA, Breyfogle B, Handa Y, De la Fonteyne L, Coleman KP
    • Issue date: 2018 Aug
    • In vitro skin irritation testing: Improving the sensitivity of the EpiDerm skin irritation test protocol.
    • Authors: Kandárová H, Hayden P, Klausner M, Kubilus J, Kearney P, Sheasgreen J
    • Issue date: 2009 Dec
    • In vitro human skin irritation test for evaluation of medical device extracts.
    • Authors: Casas JW, Lewerenz GM, Rankin EA, Willoughby JA Sr, Blakeman LC, McKim JM Jr, Coleman KP
    • Issue date: 2013 Dec
    • Preparation of irritant polymer samples for an in vitro round robin study.
    • Authors: Coleman KP, Grailer TP, McNamara LR, Rollins BL, Christiano NJ, Kandárová H, De Jong WH
    • Issue date: 2018 Aug

    DSpace software (copyright © 2002 - 2021)  DuraSpace
    Quick Guide | Contact Us
    Open Repository is a service operated by 
    Atmire NV
     

    Export search results

    The export option will allow you to export the current search results of the entered query to a file. Different formats are available for download. To export the items, click on the button corresponding with the preferred download format.

    By default, clicking on the export buttons will result in a download of the allowed maximum amount of items.

    To select a subset of the search results, click "Selective Export" button and make a selection of the items you want to export. The amount of items that can be exported at once is similarly restricted as the full export.

    After making a selection, click one of the export format buttons. The amount of items that will be exported is indicated in the bubble next to export format.