dc.description.abstractAn operator of an establishment using large quantities of dangerous substances, like ammonia, is obliged to carry out a risk assessment, in which the mortality risk to the surrounding population in the case of an accident has to be calculated. The results of the assessment are used to derive an acceptable distance between the establishment and the neighbouring dwellings. Such establishments in the Netherlands include refrigerating installations using ammonia as cooling medium. To avoid carrying out large numbers of similar risk analyses, a few representative installations have been defined. Risk analyses were carried out for these installations and results summarized in conversion tables relating the type of installation to the acceptable risk distance. The conversion table is set up for installations with a maximum of 10,000 kg of ammonia as cooling medium and a limited pump flow of less than 2 kg/s. The installations must also be in compliance with the safety recommendations of the Committee for the Prevention of Disasters. The risk to the surroundings is caused mainly by the installation parts situated outside the engine room. Therefore installations are distinguished into three types with different combinations of installation parts situated outside the engine room. Calculations show the acceptable distance to vary between zero metres for a small installation completely situated in an engine room to 95 metres for a large installation situated completely in open air. The acceptable risk distances calculated here were implemented in Dutch legislation in 2004.
dc.description.abstractBedrijven met aanzienlijke hoeveelheden gevaarlijke stoffen, zoals ammoniak, moeten een risicoanalyse maken voor de externe veiligheid. In deze analyse wordt berekend wat de risico's voor de omwonenden zijn ten gevolge van een mogelijk ongeval bij het bedrijf. De resultaten van de risicoanalyse worden vergeleken met de risiconormering en hieruit wordt een acceptabele afstand tussen het bedrijf en de omwonenden bepaald.In Nederland is een groot aantal ammoniakkoelinstallaties in gebruik. Om te voorkomen dat voor elke installatie afzonderlijk een risicoanalyse moet worden gemaakt, zijn voor een aantal representatieve installaties berekeningen uitgevoerd en is een afstandentabel samengesteld. Voor de meest voorkomende ammoniakkoelinstallaties worden nu geen aparte risicoberekeningen meer uitgevoerd, maar wordt de acceptabele afstand tot woningen uit de tabel afgelezen. De afstandentabel is opgesteld voor een ammoniakkoelinstallatie met maximaal 10.000 kg systeeminhoud, die voldoet aan de CPR richtlijnen en met een beperkt pompdebiet (minder dan 2 kg/s). Het externe veiligheidsrisico wordt voornamelijk bepaald door de onderdelen van de installatie die buiten liggen. Daarom is er onderscheid gemaakt in verschillende typen installaties, afhankelijk van de onderdelen van de installatie die buiten zijn opgesteld. De resultaten van de berekeningen laten zien dat de acceptabele afstand tussen een ammoniak koelinstallatie en woningen varieert van nul meter voor een kleine installatie die volledig in een machinekamer is opgesteld tot 95 meter voor een grote installatie die volledig buiten is opgesteld.De resultaten van de berekeningen zijn opgenomen in de Regeling Externe Veiligheid Inrichtingen (Staatscourant 23 september 2004, nr 183).
dc.format.extent316000 bytesen_US
dc.format.extent323917 bytes
dc.format.mimetypeapplication/pdf
dc.language.isonlen_US
dc.publisherRijksinstituut voor Volksgezondheid en Milieu RIVMen_US
dc.relation.ispartofseriesRIVM rapport 620100003en_US
dc.relation.urlhttp://www.rivm.nl/bibliotheek/rapporten/620100003.htmlen_US
dc.subject.otherammoniaen
dc.subject.otherrefrigerating machineryen
dc.subject.otheraccidentsen
dc.subject.othersafetyen
dc.subject.otherexternal safetyen
dc.subject.othersafety distanceen
dc.subject.otherammoniaknl
dc.subject.otherkoelinstallatiesnl
dc.subject.otherongevallennl
dc.subject.otherexterne veiligheidnl
dc.subject.otherveiligheidnl
dc.subject.otherafstandennl
dc.titleAfstandentabel ammoniak koelinstallatiesen_US
dc.title.alternativeAcceptable distances for refrigerating installations using ammonia as cooling mediumen_US
dc.typeReport
dc.contributor.departmentCEVen_US
refterms.dateFOA2018-12-18T15:24:26Z
html.description.abstractAn operator of an establishment using large quantities of dangerous substances, like ammonia, is obliged to carry out a risk assessment, in which the mortality risk to the surrounding population in the case of an accident has to be calculated. The results of the assessment are used to derive an acceptable distance between the establishment and the neighbouring dwellings. Such establishments in the Netherlands include refrigerating installations using ammonia as cooling medium. To avoid carrying out large numbers of similar risk analyses, a few representative installations have been defined. Risk analyses were carried out for these installations and results summarized in conversion tables relating the type of installation to the acceptable risk distance. The conversion table is set up for installations with a maximum of 10,000 kg of ammonia as cooling medium and a limited pump flow of less than 2 kg/s. The installations must also be in compliance with the safety recommendations of the Committee for the Prevention of Disasters. The risk to the surroundings is caused mainly by the installation parts situated outside the engine room. Therefore installations are distinguished into three types with different combinations of installation parts situated outside the engine room. Calculations show the acceptable distance to vary between zero metres for a small installation completely situated in an engine room to 95 metres for a large installation situated completely in open air. The acceptable risk distances calculated here were implemented in Dutch legislation in 2004.
html.description.abstractBedrijven met aanzienlijke hoeveelheden gevaarlijke stoffen, zoals ammoniak, moeten een risicoanalyse maken voor de externe veiligheid. In deze analyse wordt berekend wat de risico's voor de omwonenden zijn ten gevolge van een mogelijk ongeval bij het bedrijf. De resultaten van de risicoanalyse worden vergeleken met de risiconormering en hieruit wordt een acceptabele afstand tussen het bedrijf en de omwonenden bepaald.In Nederland is een groot aantal ammoniakkoelinstallaties in gebruik. Om te voorkomen dat voor elke installatie afzonderlijk een risicoanalyse moet worden gemaakt, zijn voor een aantal representatieve installaties berekeningen uitgevoerd en is een afstandentabel samengesteld. Voor de meest voorkomende ammoniakkoelinstallaties worden nu geen aparte risicoberekeningen meer uitgevoerd, maar wordt de acceptabele afstand tot woningen uit de tabel afgelezen. De afstandentabel is opgesteld voor een ammoniakkoelinstallatie met maximaal 10.000 kg systeeminhoud, die voldoet aan de CPR richtlijnen en met een beperkt pompdebiet (minder dan 2 kg/s). Het externe veiligheidsrisico wordt voornamelijk bepaald door de onderdelen van de installatie die buiten liggen. Daarom is er onderscheid gemaakt in verschillende typen installaties, afhankelijk van de onderdelen van de installatie die buiten zijn opgesteld. De resultaten van de berekeningen laten zien dat de acceptabele afstand tussen een ammoniak koelinstallatie en woningen varieert van nul meter voor een kleine installatie die volledig in een machinekamer is opgesteld tot 95 meter voor een grote installatie die volledig buiten is opgesteld.De resultaten van de berekeningen zijn opgenomen in de Regeling Externe Veiligheid Inrichtingen (Staatscourant 23 september 2004, nr 183).


Files in this item

Thumbnail
Name:
620100003.pdf
Size:
316.3Kb
Format:
PDF

This item appears in the following Collection(s)

Show simple item record