dc.description.abstractAn analytical method consisting of a nitric acid digestion and an ICP-MS analysis, has been developed for the determination of elements in food and biological material. The digestion was optimised for nitric acid concentration and destruction time. The ICP-MS analysis was optimised for minimal spectral interferences and matrix effects using interference corrections, internal standards and matrix matching of the calibration standards. Based on detection limits, reproducibility, trueness and recovery, the analytical method was found suitable for the determination of As, B, Ba, Cd, Co, Cu, Mn, Mo, Pb, Rb, Sr, Zn in food and biological material. The method was also found suitable for the determination of Al, Fe, Cr, Co, Ni in food and animal material, but not for this determination in plant material: the digestion of Al, Fe, Cr, Co and Ni in plant material was not complete. The method was found not suitable for the determination of Bi, Br, S, Se and Sn. Trueness for Sb, Si, Ti, Tl and V could not be checked, because reference materials were lacking. The elements Ca, K, Mg, Na and P can be better determined using ICP-AES because of the high concentrations.
dc.description.abstractVoor de bepaling van elementen in voeding en biotisch materiaal werd een analytische methode ontwikkeld, bestaande uit een salpeterzuurdestructie en een ICP-MS-analyse. De destructie werd geoptimaliseerd op basis van de salpeterzuurconcentratie en de destructietijd. De ICP-MS-analyse werd geoptimaliseerd op basis van minimale spectrale storingen en matrixeffecten, waarbij gebruik werd gemaakt van storingscorrecties, interne standaarden en matrix matching van de kalibratiestandaarden. Op basis van de aantoonbaarheidsgrenzen, reproduceerbaarheid, juistheid en terugvinding was de analytische methode geschikt voor de bepaling van As, B, Ba, Cd, Co, Cu, Mn, Mo, Pb, Rb, Sr, Zn in voeding en in biotisch materiaal. De methode was ook geschikt voor de bepaling van Al, Fe, Cr, Co, Ni in voeding en dierlijk materiaal, maar niet voor deze bepaling in plantaardig materiaal: de destructie van Al, Fe, Cr, Co en Ni was niet volledig. De methode was niet geschikt voor de bepaling van B, Br, S, Se en Sn. De juistheid voor Sb, Si, Ti, Tl en V kon niet worden geverifieerd, omdat referentiematerialen ontbraken. De elementen Ca, K, Mg, Na en P kunnen beter bepaald worden met ICP-AES vanwege de hoge concentraties.
dc.format.extent185000 bytesen_US
dc.format.extent381580 bytes
dc.format.mimetypeapplication/pdf
dc.language.isonlen_US
dc.publisherRijksinstituut voor Volksgezondheid en Milieu RIVMen_US
dc.relation.ispartofseriesRIVM Rapport 518001009en_US
dc.relation.urlhttp://www.rivm.nl/bibliotheek/rapporten/518001009.htmlen_US
dc.titleSalpeterzuurdestructie en ICP-MS analyse van biotisch materiaal en voedingen_US
dc.title.alternativeNitric acid digestion and ICP-MS analysis of biotic material and fooden_US
dc.contributor.departmentLACen_US
refterms.dateFOA2018-12-18T17:27:29Z
html.description.abstractAn analytical method consisting of a nitric acid digestion and an ICP-MS analysis, has been developed for the determination of elements in food and biological material. The digestion was optimised for nitric acid concentration and destruction time. The ICP-MS analysis was optimised for minimal spectral interferences and matrix effects using interference corrections, internal standards and matrix matching of the calibration standards. Based on detection limits, reproducibility, trueness and recovery, the analytical method was found suitable for the determination of As, B, Ba, Cd, Co, Cu, Mn, Mo, Pb, Rb, Sr, Zn in food and biological material. The method was also found suitable for the determination of Al, Fe, Cr, Co, Ni in food and animal material, but not for this determination in plant material: the digestion of Al, Fe, Cr, Co and Ni in plant material was not complete. The method was found not suitable for the determination of Bi, Br, S, Se and Sn. Trueness for Sb, Si, Ti, Tl and V could not be checked, because reference materials were lacking. The elements Ca, K, Mg, Na and P can be better determined using ICP-AES because of the high concentrations.
html.description.abstractVoor de bepaling van elementen in voeding en biotisch materiaal werd een analytische methode ontwikkeld, bestaande uit een salpeterzuurdestructie en een ICP-MS-analyse. De destructie werd geoptimaliseerd op basis van de salpeterzuurconcentratie en de destructietijd. De ICP-MS-analyse werd geoptimaliseerd op basis van minimale spectrale storingen en matrixeffecten, waarbij gebruik werd gemaakt van storingscorrecties, interne standaarden en matrix matching van de kalibratiestandaarden. Op basis van de aantoonbaarheidsgrenzen, reproduceerbaarheid, juistheid en terugvinding was de analytische methode geschikt voor de bepaling van As, B, Ba, Cd, Co, Cu, Mn, Mo, Pb, Rb, Sr, Zn in voeding en in biotisch materiaal. De methode was ook geschikt voor de bepaling van Al, Fe, Cr, Co, Ni in voeding en dierlijk materiaal, maar niet voor deze bepaling in plantaardig materiaal: de destructie van Al, Fe, Cr, Co en Ni was niet volledig. De methode was niet geschikt voor de bepaling van B, Br, S, Se en Sn. De juistheid voor Sb, Si, Ti, Tl en V kon niet worden geverifieerd, omdat referentiematerialen ontbraken. De elementen Ca, K, Mg, Na en P kunnen beter bepaald worden met ICP-AES vanwege de hoge concentraties.


Files in this item

Thumbnail
Name:
518001009.pdf
Size:
372.6Kb
Format:
PDF

This item appears in the following Collection(s)

Show simple item record