dc.description.abstractResults are described here of performance characteristics of an automated ion chromatographic method for the simultaneous determinations of analytes in water. The microbore gradient method is equipped with an on-line eluent generator and a microbore suppressor in the recycling mode. The repeatability, trueness, recovery, limits of detection and matrix effects were investigated. No pretreatment was necessary for most of the regular matrices. The repeatability for chloride between 1.2 and 12 mmol/l; nitrate between 0.2 and 2 mmo/l, sulfate between 0.1 and 1.2 mmol/l and bromide between 0.05 and 0.5 mmol/l is better than 0.9%. The repeatability for nitrite at 10 4mol/l and 100 4mol/l is 3.40% and 0.67%, respectively. The limits of detection for chloride, nitrate, nitrite, sulfate and bromide amounted to 2 4mol/l. Application of the method was tested for drinking water, rainwater, groundwater, surface water and water extracts from air filters. The results of the analysis have been compared with previous applied methods.
dc.description.abstractDit rapport beschrijft de resultaten van het onderzoek naar de prestatiekenmerken van een geautomatiseerde ionchromatografische methode voor de gelijktijdige bepalingen van eerdere anionen in diverse typen water. De micro-bore gradient methode is voorzien van een on-line eluens generator en een microbore suppressor in de recycling mode. Onder andere de terugvinding, de standaardafwijking van de herhaalbaarheid en de juistheid in grond- en regenwater zijn vastgesteld. De procentuele variatiecoefficienten voor chloride in het meetbereik tussen 1,2 en 12 mmol/l, nitraat tussen 0,2 en 2 mmol/l, sulfaat tussen 0,1 en 1,2 en bromide tussen 0,05 en 0,5 mmol/l zijn beter dan 0,9 %. Voor nitriet bedragen deze waarden bij 10 umol/l en 100 umol/l respectievelijk 3,4 en 0,67 %. De aantoonbaarheidsgrenzen voor chloride, nitraat, nitriet, sulfiet, sulfaat, en bromide bedragen 2 umol/l. De toepasbaarheid van de methode is getoetst in diverse matrices, zoals regenwatermonsters, drinkwatermonsters, een CRM, grondwatermonsters en extracten van luchtfilters. De resultaten van ionchromatografische analyses van verschillende systemen in diverse matrices zijn vergeleken. Voorbehandeling is voor de meeste analyses niet noodzakelijk. Het onderzoek werd verricht in de periode januari 1999 tot februari 2000.
dc.format.extent144000 bytesen_US
dc.format.extent146962 bytes
dc.format.mimetypeapplication/pdf
dc.identifier518001008en_US
dc.identifier.urihttp://hdl.handle.net/10029/9536
dc.language.isonlen_US
dc.publisherRijksinstituut voor Volksgezondheid en Milieu RIVMen_US
dc.relation.ispartofseriesRIVM Rapport 518001008en_US
dc.relation.urlhttp://www.rivm.nl/bibliotheek/rapporten/518001008.htmlen_US
dc.titlePrestatiekenmerken en validatie van anionchromatografische analyses in verschillende matricesen_US
dc.title.alternativePerformance characteristics and validation of anionchromatographic analysis in different matricesen_US
dc.typeReport
dspace.entity.typePublication
html.description.abstract<p>Results are described here of performance characteristics of an automated ion chromatographic method for the simultaneous determinations of analytes in water. The microbore gradient method is equipped with an on-line eluent generator and a microbore suppressor in the recycling mode. The repeatability, trueness, recovery, limits of detection and matrix effects were investigated. No pretreatment was necessary for most of the regular matrices. The repeatability for chloride between 1.2 and 12 mmol/l; nitrate between 0.2 and 2 mmo/l, sulfate between 0.1 and 1.2 mmol/l and bromide between 0.05 and 0.5 mmol/l is better than 0.9%. The repeatability for nitrite at 10 4mol/l and 100 4mol/l is 3.40% and 0.67%, respectively. The limits of detection for chloride, nitrate, nitrite, sulfate and bromide amounted to 2 4mol/l. Application of the method was tested for drinking water, rainwater, groundwater, surface water and water extracts from air filters. The results of the analysis have been compared with previous applied methods.</p>
html.description.abstract<p> Dit rapport beschrijft de resultaten van het onderzoek naar de prestatiekenmerken van een geautomatiseerde ionchromatografische methode voor de gelijktijdige bepalingen van eerdere anionen in diverse typen water. De micro-bore gradient methode is voorzien van een on-line eluens generator en een microbore suppressor in de recycling mode. Onder andere de terugvinding, de standaardafwijking van de herhaalbaarheid en de juistheid in grond- en regenwater zijn vastgesteld. De procentuele variatiecoefficienten voor chloride in het meetbereik tussen 1,2 en 12 mmol/l, nitraat tussen 0,2 en 2 mmol/l, sulfaat tussen 0,1 en 1,2 en bromide tussen 0,05 en 0,5 mmol/l zijn beter dan 0,9 %. Voor nitriet bedragen deze waarden bij 10 umol/l en 100 umol/l respectievelijk 3,4 en 0,67 %. De aantoonbaarheidsgrenzen voor chloride, nitraat, nitriet, sulfiet, sulfaat, en bromide bedragen 2 umol/l. De toepasbaarheid van de methode is getoetst in diverse matrices, zoals regenwatermonsters, drinkwatermonsters, een CRM, grondwatermonsters en extracten van luchtfilters. De resultaten van ionchromatografische analyses van verschillende systemen in diverse matrices zijn vergeleken. Voorbehandeling is voor de meeste analyses niet noodzakelijk. Het onderzoek werd verricht in de periode januari 1999 tot februari 2000.</p>
refterms.dateFOA2018-12-18T17:27:23Z
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
518001008.pdf
Size:
143.52 KB
Format:
Adobe Portable Document Format