Abstract
Abstract niet beschikbaar
Emission measurements at the municipal solid waste incinerator (MSWI) AVI-Philips in Eindhoven show an average dioxin concentration in the stack gas of 7,7 ng TEQ/Nm3 (dry, 11% oxygen) at normal operation of the installation. This concentration is considered to be low for this type of installation, when compared with other types of MSWIs in the Netherlands. The yearly emission of dioxins from this installation is estimated at 1,1 g TEQ. According to dispersion model calculations this emission only has a small contribution to the yearly mean deposition in the surroundings, viz. on average 0,2 ng TEQ/(m2.year) over an area of 20x20 km2 with a maximum of 1,9 ng TEQ/(m2,year) at 1.000 m North- East of the installation. Background depositions are estimated at 10 ng TEQ/(m2.year). Direct danger for public health is not expected and determination of dioxin levels in grass and soil in this area is not recommended.
Emission measurements at the municipal solid waste incinerator (MSWI) AVI-Philips in Eindhoven show an average dioxin concentration in the stack gas of 7,7 ng TEQ/Nm3 (dry, 11% oxygen) at normal operation of the installation. This concentration is considered to be low for this type of installation, when compared with other types of MSWIs in the Netherlands. The yearly emission of dioxins from this installation is estimated at 1,1 g TEQ. According to dispersion model calculations this emission only has a small contribution to the yearly mean deposition in the surroundings, viz. on average 0,2 ng TEQ/(m2.year) over an area of 20x20 km2 with a maximum of 1,9 ng TEQ/(m2,year) at 1.000 m North- East of the installation. Background depositions are estimated at 10 ng TEQ/(m2.year). Direct danger for public health is not expected and determination of dioxin levels in grass and soil in this area is not recommended.
Description
Publisher
Sponsors
HIMH